Jungheinrich ERC 214 [179/214] Õungheinrich event messages

Jungheinrich ERC 214 [179/214] Õungheinrich event messages
õUNGHEINRICH Event Messages
03.15179
G
_7591Operation
UPC specific:
The job could not be
completed
Order runtime in controller exceeded
-Manually reverse the shuttle, start the job again
-Check sensors for contamination, incorrect
settings and faults
-Check pallet
-Check rail holes for contamination
-Test drive system (manual travel)
-If the shuttle remains near a rail hole, you may
need to adjust the pallet distance parameters or
the channel end distance parameters slightly.
_7601Operation
UPC specific:
Pallet lift error at start
Incorrect signal constellation at sensors 7B37.1 - 7B37.4
No signals from incremental transmitter 1B5
-Repeat travel job
-Position pallet correctly at first pallet location
-Check pallet
-Check pallet detection sensors 7B37.1-7B37.4
for contamination, incorrect settings and faults
-Check incremental transmitter 1B5
-Check wire connection
-Check drive chain
_7602Operation
UPC specific:
Pallet lift error
Incorrect signal constellation at sensors 7B37.1 - 7B37.4
-Manually reverse shuttle
-Repeat travel job
-Check pallet
-Check pallet detection sensors 7B37.1-7B37.4
for contamination, incorrect settings and faults
-Check wire connection.
_7611Operation
UPC specific:
Obstacle detection
Negative signal at sensors 7B34.1 - 7B34.4
-Manually reverse shuttle while checking for
possible obstacles in the way of the shuttle
-Check obstacle sensors 7B34.1 - 7B34.4 for
contamination, incorrect settings and faults
-Check wire connection
-Check channel for obstacles (load, wooden
remains and shrink wrap)
-Check channel for possible reflection causes
F E XX SOperational
Status
DescriptionCause / Triggering EventAction

Содержание

Похожие устройства