õUNGHEINRICH Event Messages
03.1518
G
_11721Operation
LH load wheel sensor
excessive deviation from
reading to drive wheel
Incorrect counting detected between LH load wheel
sensor and drive wheel incrementer.
-Check mounting position of sensor to magnet;
-Check tyre quality;
-Replace sensor;
_11722Operation
RH load wheel sensor
excessive deviation from
reading to drive wheel
Incorrect counting detected between RH load wheel
sensor and drive wheel incrementer.
-Check mounting position of sensor to magnet;
-Check tyre quality;
-Replace sensor;
_11723Operation
Three channel incrementer
comparison with sensor
bearing incrementer
The sensor bearing and three channel incrementer are
synchronised with respect to each other every 120 mm.
The error is generated if the sensor bearing deviates
from the three channel sensor by >= 5 mm.
-Test the electrical function of the sensor bearing
-Test the mechanical function of the sensor
bearing
_1181Undefined
Speed sensor in load wheel
sensor damaged
This event message is not currently used.
-Check speed sensor power supply;
-Check wire connection;
-Replace speed sensor;
-Replace signal-evaluating controller;
_1191OperationCabin position implausible
The event message is triggered
if for T >= time limit the following applies:
A change in status of the platform lower-limit sensor
from the neutral position into the "Platform raised"
position is detected while driving
-Check wiring from controller to platform lower
limit sensor;
-Check / replace lower limit sensor;
-Check lift motor power cables;
- Replace the signal-generating controller;
F E XX SOperational
Status
DescriptionCause / Triggering EventAction