Jungheinrich ERC 214 [10/214] Õungheinrich event messages

Jungheinrich ERC 214 [10/214] Õungheinrich event messages
õUNGHEINRICH Event Messages
03.1510
G
_1084
Self test
Operation
Handbrake lever redundant
inputs logic implausible
The "handbrake lever" switch consists of a NC and a NO
contact. When the button is pressed both contacts switch
simultaneously. As a result, only the 0/1 and 1/0
combinations should occur.
During operation the combinations
0/0 and 1/1 (switched for 500msec.) activate the event
message.
For a valid combination (0/1 or 1/0, switched for
500msec) the event message and the truck's response
are reset.
-Check wire connections;
-Check handbrake lever switch;
-Replace handbrake lever” switch;
_1085
Self test
Operation
Parking brake switch
redundant inputs logic
implausible
The "parking brake" switch consists of a NC and a NO
contact. When the button is pressed both contacts switch
simultaneously. As a result, only the 0/1 and 1/0
combinations should occur.
During operation the combinations
0/0 and 1/1 (switched for 500msec.) activate the event
message.
For a valid combination (0/1 or 1/0, switched for 500
msec.) the event message and the truck's response are
reset.
-Check wire connections;
-Check options keypad;
-Replace options keypad:
_1091Operation
Weigher button inputs
implausible
The weigher button consists of a NC and a NO contact.
When the button is pressed both contacts connect
simultaneously. As a result, only the 0/1 and 1/0
combinations should occur.
During operation combinations 0/0 and 1/1 (500msec.)
trigger the event message.
For a valid combination (0/1 or 1/0, 500msec) the event
message and the truck response are reset.
-Check wire connection;
-Check weigher button;
-Replace weigher button;
F E XX SOperational