Jungheinrich ERC 214 [118/214] Õungheinrich event messages

Jungheinrich ERC 214 [118/214] Õungheinrich event messages
õUNGHEINRICH Event Messages
03.15118
G
_5021Operation
Internal processor control
implausible
This event message is triggered
if for T < 10msec the "external watchdog" hardware
signal is implausible (processed too quickly).
-Switch the truck off and on again;
-Replace component;
_5022Operation
Internal processor control
implausible
This event message is triggered
if for T > 100msec the "external watchdog" hardware
signal is implausible (processed too slowly).
-Switch the truck off and on again;
-Replace component;
_5023Self test
"External watchdog"
hardware signal improbable
(not output stage disable)
When the external watchdog runs out the output
transformers / basic outputs are not switched off.
"External watchdog" hardware signal implausible
Signal permanently displayed / output transformer not
deactivated.
-Switch the truck off and on again;
-Replace component;
_5024Operation
Internal processor control
implausible
This event message is triggered
if the "external watchdog" does not start within 10msec.
-Switch the truck off and on again;
-Replace component;
_5025Operation
Internal processor control
implausible
This event message is triggered
if the initial activation of the external watchdog was not
successful.
-Switch the truck off and on again;
-Replace component;
_5031…n
System start
Operation
EEProm does not respond
This event message is triggered
if the EEPROM has not responded forty times in
succession.
-Clear logbook;
-Set truck type;
-Set hour meter;
-Set default parameters;
-Replace controller;
F E XX SOperational
Status
DescriptionCause / Triggering EventAction