Jungheinrich ERC 214 [103/214] Õungheinrich event messages

Jungheinrich ERC 214 [103/214] Õungheinrich event messages
õUNGHEINRICH Event Messages
03.15103
G
_33935Operation
Power supply line driver jxp-
Interface IDS, system B out
of range
Power supply for output driver 1 (24 V) in CANopen
slave less than 14V
-Measure voltage output without load;
-Check connected actuating system for
permissible current consumption;
-Replace component;
_33936Operation
Power supply line driver jxp-
L, system B out of range
Power supply for output driver 1 (24 V) in CANopen
slave less than 14V
-Measure voltage output without load;
-Check connected actuating system for
permissible current consumption;
-Replace component;
_33938Operation
Power supply line driver jxp-
Interface DPI, system B out
of range
Power supply for output driver 1 (24 V) in CANopen
slave less than 14V
-Measure voltage output without load;
-Check connected actuating system for
permissible current consumption;
-Replace component;
_33939Operation
Power supply line driver jxp-
Interface MIO, system B out
of range
Power supply for output driver 1 (24 V) in CANopen
slave less than 14V
-Measure voltage output without load;
-Check connected actuating system for
permissible current consumption;
-Replace component;
_33953Operation
Power supply line driver jxp-
E1, system B out of range
Power supply for output driver 1 (24 V) in CANopen
slave less than 14V
-Measure voltage output without load;
-Check connected actuating system for
permissible current consumption;
-Replace component;
_33954Operation
Power supply line driver jxp-
E2, system B out of range
Power supply for output driver 1 (24 V) in CANopen
slave less than 14V
-Measure voltage output without load;
-Check connected actuating system for
permissible current consumption;
-Replace component;
_33955Operation
Power supply line driver jxp-
E1 optional (drive
compartment), system B out
of range
Power supply for output driver 1 (24 V) in CANopen
slave less than 14V
-Measure voltage output without load;
-Check connected actuating system for
permissible current consumption;
-Replace component;
F E XX SOperational
Status
DescriptionCause / Triggering EventAction

Содержание