õUNGHEINRICH Event Messages
03.15114
G
_4061nOperation
Critical motor over-
temperature
"Motor" temperature range exceeded
(critical)
The event is triggered when the following applies
(hysteresis):
"On" when temperature > upper temperature limit;
"Off" when temperature < upper temperature limit
- 5 °C.
-Allow the motor to cool down;
-Check ventilation inputs and outputs, clean if
necessary;
-Check fan controller parameters;
-Check brakes can move freely;
-Test fans and replace if necessary;
_4071nUndefined
Internal components
temperature range not
achieved (significantly)
The event is triggered when the following applies
(hysteresis):
"On" when temperature < temperature limit;
"Off" when temperature > temperature limit + hysteresis
value
-Measure the temperature at the location of the
component;
-Measure the temperature of the component;
-Compare the temperatures and replace the
component if necessary;
_4081Undefined
Significant battery over-
temperature
The event is triggered when the following applies:
Cell temperature > limiting value 1
-Allow battery to cool;
-Check temperature measurement;
-Check harness;
-Replace battery controller;
-Replace Battery Management System (BMS);
-Replace battery (if the problem occurs
repeatedly)
_4091Undefined
Battery temperature over-
exceeded
The event is triggered when the following applies:
Cell temperature > limiting value 2
-Allow battery to cool;
-Check temperature measurement;
-Check harness;
-Replace battery controller;
-Replace Battery Management System (BMS);
-Replace battery (if the problem occurs
repeatedly)
F E XX SOperational
Status
DescriptionCause / Triggering EventAction