Citizen CT-E651L Руководство по эксплуатации онлайн [70/72] 632555

Citizen CT-E651L Руководство по эксплуатации онлайн [70/72] 632555
70
Switch no. Function OFF ON
MSW5-1 Buzzer Valid Invalid
MSW5-2 Line Pitch 1/360 1/406
MSW5-3 USB Mode Virtual COM Printer Class
MSW5-4 Reserved Fixed
MSW5-5 Reserved Fixed
MSW5-6 Reserved Fixed
MSW5-7 Reserved Fixed
MSW5-8 Reserved Fixed
MSW6-1 Act. For Driver Invalid Valid
MSW6-2 Character Space Invalid Valid
MSW6-3 USB Power Save Invalid Valid
MSW6-4 Reserved Fixed
MSW6-5 Reserved Fixed
MSW6-6 Reserved Fixed
MSW6-7 Reserved Fixed
MSW6-8 Power ON trigger Power switch ON AC power input
Switch no. Function Initial setting Setting value
MSW7-1 Baud Rate 9600 bps 1200 bps, 2400 bps, 4800 bps, 9600 bps, 19200 bps,
38400 bps, 57600 bps, 115200 bps
MSW7-2 Data Length 8bits 7bits, 8bits
MSW7-3 Stop Bit 1bit 1bit, 2bits
MSW7-4 Parity NONE NONE, ODD, EVEN
MSW7-5 Flow Control DTR/DSR DTR/DSR, XON/XOFF
MSW7-6 DMA Control Valid Valid, Invalid
MSW7-7 VCom Protocol PC Setting PC Setting, DTR/DSR, XON/XOFF
MSW8-1 Print Width 576 dots 576 dots, 546 dots, 512 dots, 420 dots, 390 dots, 384
dots, 360 dots
MSW8-3 Top Margin 11mm 3mm, 4mm, 5mm, 6mm, 7mm, 8mm, 9mm, 10mm,
11mm
MSW8-4 Line Gap Reduce Invalid Invalid, 3/4, 2/3, 1/2, 1/3, 1/4, 1/5, ALL
MSW8-5 Reduced Char V/H 100% / 100% 100% / 100%, 75% / 100%, 50% / 100%, 100% / 75%,
75% / 75%, 50% / 75%
MSW8-6 Auto Side Shift Invalid Invalid, 1 dot, 2 dots, 3 dots, 4 dots, 5 dots, 6 dots, 7
dots
MSW8-7 Liner Free Mode Invalid Disabled, 1 h, 6 h, 12 h, 18 h, 24 h, 5 m, 10 m
15 m, 20 m, 30 m

Содержание

Скачать