Zyxel IES-1000 EE [100/368] Alarm port setup screen

Zyxel IES-1000 EE [100/368] Alarm port setup screen
Chapter 16 Alarm
VOP1224-61 User’s Guide
100
16.5 Alarm Port Setup Screen
Use this screen to set the alarm severity threshold for recording alarms on an
individual port(s). The system reports an alarm on a port if the alarm has a
severity equal to or higher than the port’s threshold.
To open this screen, click Alarm > Alarm Port Setup.
Figure 40 Alarm Port Setup
Syslog Select this check box to have the system send this alarm to a syslog
server.
Severity Select an alarm severity level (critical, major, minor or info) for
this alarm. Critical alarms are the most severe, major alarms are the
second most severe, minor alarms are the third most severe and info
alarms are the least severe.
Clearable Select this check box to allow administrators to use the management
interface to remove an alarm report generated by this alarm event
entry.
Select this check box to keep an alarm report generated by this alarm
event in the system until the conditions that caused the alarm report
are no longer present.
Apply Click Apply to save your changes to the VOP’s volatile memory. The
VOP loses these changes if it is turned off or loses power, so use the
Config Save link on the navigation panel to save your changes to the
non-volatile memory when you are done configuring.
Close Click Close to exit the screen without saving your changes.
Table 30 Alarm Event Setup Edit (continued)
LABEL DESCRIPTION