Zyxel IES-1000 EE [97/368] Alarm event setup screen

Zyxel IES-1000 EE [97/368] Alarm event setup screen
Chapter 16 Alarm
VOP1224-61 User’s Guide
97
16.4 Alarm Event Setup Screen
This screen lists the alarms that the system can generate along with the severity
levels of the alarms and where the system is to send them.
eqpt (10004)hw_mon_fail critical The hardware monitor
diagnosis test failed.
eqpt (10005)cold_start info System cold-start.
eqpt (10006)warm_start info System warm-start.
eqpt (10007)voip_clock_fail critical The SLIC clock failed.
eqpt (10008)voip_battery_fail critical The VoIP battery failed.
sys (15000)reboot info The system restarted.
sys (15002)alm_clear info V An administrator cleared the
alarms.
sys (15003)login_fail minor V Someone used the wrong
name or password and failed
to log in.
enet (20000)up info A Gigabit Ethernet interface
is up.
enet (20001)down major V An Ethernet interface is
down.
voip (25000)voip_temp_error critical The SLIC temperature
exceeded its upper limit.
voip (25001)voip_dc_power_fail critical The SLIC experienced a DC
power fault.
voip (25002)voip_ac_power_fail critical The SLIC experienced an AC
power fault.
voip (25003)voip_ring_timer_fail info The ring timer could not be
started.
voip (25004)voip_ring_rsrce_fail info Ring resources could not be
obtained.
voip (25505)voip_ring_ohd_fail info There was a high load
indication when ringing a
port.
voip (25506)voip_long_loop_fail info The phone loop was too
long.
Table 28 Alarm Descriptions (continued)
ALARM CONDITION SEVERITY CLEARABLE DESCRIPTION

Содержание