Zyxel IES-1000 EE [153/368] Table 53 log messages continued

Zyxel IES-1000 EE [153/368] Table 53 log messages continued
Chapter 19 Diagnostic
VOP1224-61 User’s Guide
153
Received Firmware
Checksum Error!
WARN A checksum error was detected during an attempted
FTP firmware upload.
Received Firmware Size
too large!
WARN The file size was too large with an attempted FTP
firmware upload.
Received Firmware
Invalid!
WARN Someone attempted to upload a firmware file with a
wrong identity via FTP.
Received File <file>! INFO A file was uploaded to the VOP by FTP.
<file> - received file’s name
THERMO OVER
TEMPERATURE: dev:<id>
threshold:<threshold>
(degree C)
value:<temp>(degree
C)!
WARN The temperature was too high at one of the
temperature sensors.
<id> -
0: sensor near the VoIP SLIC (Subscriber Line
Interface Card)
1: sensor at the hardware monitor chip near the
central processing unit
2: sensor near the VoIP battery
<threshold> - threshold temperature
<temp> - temperature when the entry was logged
THERMO OVER
TEMPERATURE released:
dev:<id>
threshold:<threshold>
(degree C)
value:<temp>(degree
C)!
INFO The temperature at one of the temperature sensors
has come back to normal.
<id>
0: sensor near the VoIP SLIC (Subscriber Line
Interface Card)
1: sensor at the hardware monitor chip near the
central processing unit
2: sensor near the VoIP battery
<threshold> - threshold temperature
<temp> - temperature when the entry was logged
THERMO OVER VOLTAGE:
nominal:<nominal>(mV)
value:<voltage> mV)!
WARN The voltage went outside of the accepted operating
range.
<nominal> - nominal voltage of the DC power
<voltage> - voltage of the DC power when logged
THERMO OVER VOLTAGE
released:
nominal:<nominal>(mV)
value:<voltage> (mV)!
INFO The voltage is back inside the accepted operating
range.
<nominal> - nominal voltage of the DC power
<voltage> - voltage of the DC power when logged
Table 53 Log Messages (continued)
LOG MESSAGE TYPE DESCRIPTION

Содержание