Zyxel IES-1000 EE [177/368] Table 64 log messages continued

Zyxel IES-1000 EE [177/368] Table 64 log messages continued
Chapter 24 System Commands
VOP1224-61 User’s Guide
177
THERMO LOW
TEMPERATURE: dev:<id>
threshold:<threshold>
(degree C)
value:<temp>(degree
C)!
WARN The temperature was too low at one of the temperature sensors.
id -
0: sensor near the VoIP SLIC (Subscriber Line Interface Card)
1: sensor at the hardware monitor chip near the central
processing unit
2: sensor near the VoIP battery
threshold - temperature limit
temp - temperature when the entry was logged
THERMO OVER
TEMPERATURE: dev:<id>
threshold:<threshold>
(degree C)
value:<temp>(degree
C)!
WARN The temperature was too high at one of the temperature sensors.
id -
0: sensor near the VoIP SLIC (Subscriber Line Interface Card)
1: sensor at the hardware monitor chip near the central
processing unit
2: sensor near the VoIP battery
threshold - temperature limit
temp - temperature when the entry was logged
THERMO OVER
TEMPERATURE released:
dev:<id>
threshold:<threshold>
(degree C)
value:<temp>(degree
C)!
INFO The temperature at one of the temperature sensors has come
back to normal.
id -
0: sensor near the VoIP SLIC (Subscriber Line Interface Card)
1: sensor at the hardware monitor chip near the central
processing unit
2: sensor near the VoIP battery
threshold - temperature limit
temp - temperature when the entry was logged
THERMO OVER VOLTAGE:
dev: <id> limit:
<threshold> value:
<voltage>!
WARN The voltage at one of the voltage sensors went above the
accepted operating range.
id - 1=1.2v, 2=1.8v, 3=3.3v, 4=24v
threshold - voltage limit
voltage - voltage of the DC power when logged
THERMO OVER VOLTAGE
released:
nominal:<nominal>(mV)
value:<voltage> (mV)!
INFO The device’s voltage is back inside the accepted operating range.
nominal - nominal voltage of the DC power
voltage - voltage of the DC power when logged
Table 64 Log Messages (continued)
LOG MESSAGE TYPE DESCRIPTION

Содержание