Zyxel IES-1000 EE [98/368] Figure 38 alarm event setup

Zyxel IES-1000 EE [98/368] Figure 38 alarm event setup
Chapter 16 Alarm
VOP1224-61 User’s Guide
98
To open this screen, click Alarm > Alarm Event Setup.
Figure 38 Alarm Event Setup
The following table describes the labels in this screen.
Table 29 Alarm Event Setup
LABEL DESCRIPTION
Index This field displays the index number of the alarm in the list. Click this
to specify the severity level of an alarm(s) and where the system is to
send the alarm(s). See Section 16.4.1 on page 99.
Alarm This field displays the alarm category to which the alarm belongs.
eqpt represents equipment alarms.
enet represents Ethernet alarms.
sys represents system alarms.
voip represents Voice over IP alarms.
Condition Code This field displays the condition code number for the specific alarm
message.
Condition This field displays a text description for the condition under which the
alarm applies.
Facility This field displays the log facility (Local 1~ Local 7) on the syslog
server where the system is to log this alarm. This is for alarms that
send alarms to a syslog server.
SNMP This field displays “V” if the system is to send this alarm to an SNMP
server. It displays “-“ if the system does not send this alarm to an
SNMP server.

Содержание