Chapter 16 Alarm
VOP1224-61 User’s Guide
96
The following table describes the labels in this screen.
16.3 Alarm Descriptions
This table describes alarms that the system can send.
ATUC refers to the downstream channel (for traffic going from the VOP to the
subscriber). ATUR refers to the upstream channel (for traffic coming from the
subscriber to the VOP). A “V” in the CLEARABLE column indicates that an
administrator can remove the alarm (by default).
Table 27 Alarm Status
LABEL DESCRIPTION
Alarm Type Select which type of alarms to display by Severity, or select All to
look at all the alarms.
Refresh Click this button to update this screen.
Clear Click this button to erase the clearable alarm entries.
No This field displays the index number of the alarm entry in the system.
Alarm This field displays the alarm category to which the alarm belongs.
Condition This field displays a text description for the condition under which the
alarm applies.
Source This field displays where the alarm originated. This is either a port
number, one of the Ethernet ports (enet 1 or 2), or “eqpt” for the
system itself.
Severity This field displays the alarm severity level (critical, major, minor or
info).
Timestamp This field displays the month, day, hour, minute and second that the
system created the log.
Page X of Y This identifies which page of information is displayed and the total
number of pages of information.
Previous Page Click this to display the preceding page of entries.
Next Page Click this to display the following page of entries.
Table 28 Alarm Descriptions
ALARM CONDITION SEVERITY CLEARABLE DESCRIPTION
eqpt (10000)vol_err critical The input voltage (Vn) is
lower than the low-threshold
or higher than the high-
threshold.
eqpt (10001)temp_err critical The temperature (Tn) is
higher than the high-
threshold or lower than the
low-threshold.
eqpt (10003)hw_rtc_fail critical The Real Time Chip diagnosis
test failed.