Sagi KUBA (внутренний агрегат) [32/116] Loading the product

Sagi KIAA (внутренний агрегат) [32/116] Loading the product
16
The defrost led is reset to standard operation
The display shows [rES] after the abnormal event.
If the high temperature alarm is on, the compressor keeps working; if the low temperature alarm is on, the compressor stops.
! If the card is set to the stand-by mode, the min. / max. temperature memorized and any alarms will not be saved.
BLACKOUT ALARM
The defrost led blinking at high frequency indicates a blackout
The display shows [bL O].
The display shows the max. room temperature memorized.
The defrost led is reset to standard operation.
The display shows [rES] after the abnormal event.
INTELLIGENT DEFROST
INTELLIGENT DEFROST: a totally automatic system allowing to start defrost cycles only if it is necessary.
In pursuance of an energy saving policy and for best foodstuffs storing, defrost cycles are automatically performed not at pre-set
intervals but according to the evaporator state.
The control card is able to monitor operation through some functional parameters: defrost starts only if it is really necessary, which
basically depends on the type of use of the appliance and on the type of foodstuffs stored.
ENERGY SAVING
ENERGY SAVING: a totally automatic system which allows energy saving through the use of the appliance
This system operates when the appliance is not being used, with door closed, and constant inside temperature close to the setpoint value.
This function stops in the following cases:
- manual or automatic defrost activation
- manual activation of Hiper Cold function
- room temperature reading out of the set parameters
- operation with faulty room probe
- manual variation of the room setpoint
- different setting of evaporator fan operation
LOADING THE PRODUCT
Distribute the product evenly inside the refrigerated
compartments so as to allow adequate air circulation;
Do not obstruct the ventilation areas of the cooling
system located on the left of the compartment;
Do not use the lower drawer on the right to store
foodstuffs requiring low-temperature storing;
Cover or wrap foodstuffs with specific protective films
before storing;
Do not introduce hot foodstuffs or beverages;
Do not leave the door open longer than is necessary
when introducing or removing products.
STOPPING
To stop operation at any time, position the main switch on
OFF. The button turns off.
To disconnect the counter from the power supply, remove the
plug from the outlet.
MALFUNCTIONING
In case of malfunctioning, before contacting the technical
service, check that:
the main switch is lit and the mains supply is present
the temperature is set at the desired value
the doors are perfectly closed