D-Link DGS-1210-52/ME rev.A [162/457] Create syslog host

D-Link DGS-1210-52/ME rev.A [162/457] Create syslog host
DGS-1210 Metro Ethernet Managed Switch CLI Reference Guide
144
Syslog Global State: Enabled
DGS-1210-28P/ME:5#
create syslog host
Purpose
To create a new syslog host.
Syntax
create syslog host <index 1-4> ipaddress [<ipaddr> |
<ipv6addr>] {severity [informational | warning | all] | facility
[local0 | local1| local2 | local3 | local4 | local5 | local6 | local7] |
state [enable | disable] | udp_port [514 | <udp_port_number
6000-65535>]}
Description
The create syslog host command creates a new syslog host.
Parameters
all − Specifies that the command is to be applied to all hosts.
<index 1-4> The syslog host index id. There are four available
indices, numbered 1 to 4.
ipaddress [<ipaddr> | <ipv6addr>] The IPv4 or IPv6 address of the
remote host to which syslog messages are to be sent.
severity The message severity level indicator. These are
DGScribed in the table below (Bold font indicates that the
corresponding severity level is currently supported on the Switch):
Numerical Severity
Code
0 Emergency: system is unusable
1 Alert: action must be taken immediately
2 Critical: critical conditions
3 Error: error conditions
4 Warning: warning conditions
5 Notice: normal but significant condition
6 Informational: informational messages
7 Debug: debug-level messages
informational Specifies that informational messages are to be sent
to the remote host. This corresponds to number 6 from the list
above.
warning Specifies that warning messages are to be sent to the
remote host. This corresponds to number 4 from the list above.
all − Specifies that all message are to be sent to the remote host.
facility Some of the operating system daemons and processes
have been assigned Facility values. Processes and daemons that
have not been explicitly assigned a Facility may use any of the local
use facilities or they may use the user-level Facility. Those
Facilities that have been DGSignated are shown in the table below
(Bold font indicates the facility values that the Switch currently
supports):