D-Link DGS-1210-52/ME rev.A [315/457] Config ddm power_unit

D-Link DGS-1210-52/ME rev.A [315/457] Config ddm power_unit
DGS-1210/ME Metro Ethernet Switch CLI Reference Guide
297
To configure the port 21’s voltage threshold:
DGS-1210-28P/ME:5# config ddm ports 1:21 temperature_threshold
high_alarm 84.9555 low_alarm -10 high_warning 70 low_warning
2.25251
Command: config ddm ports 1:21 temperature_threshold high_alarm
84.9555 low_alarm -10 high_warning 70 low_warning 2.25251
Success.
DGS-1210-28P/ME:5#
config ddm power_unit
Purpose
To configure the unit of DDM TX and RX power.
Syntax
config ddm power_unit [mw | dbm]
Description
The config ddm power_unit command is used to configure the unit
of DDM TX and RX power.
Parameters
mw - Specify the DDM TX and RX power unit as mW.
dbm - Specify the DDM TX and RX power unit as dBm.
Restrictions
Only Administrator or operator-level users can issue this command.
Example usage:
To configure the DDM TX and RX power unit as dBm:
DGS-1210-28P/ME:5# config ddm power_unit dbm
Command: config ddm power_unit dbm
Success.
DGS-1210-28P/ME:5#
show ddm ports
Purpose
To display the current operating DDM parameters and configuration
values of the optic module of the specified ports.
Syntax
show ddm ports <portlist> [configuration | status | vender_info]
Description
The config ddm power_unit command is used to display the
current operating DDM parameters and configuration values of the
optic module of the specified ports.
Parameters
<portlist> - Specify the ports of DDM to be displayed.
configuration - Specifies that the configuration values will be
displayed.
status - Specifies that the operating parameter will be displayed.
vender_info - Specifies that the vender information will be displayed.
Restrictions
None.
Example usage:
To display ports 1-5’s operating parameters:

Содержание

Похожие устройства