Emotron CDU/CDX 48-026 [34/82] Important master programs factory setting

Emotron CDU/CDX 48-026 [34/82] Important master programs factory setting
EMOTRON DSV 5445/5444
Page 34
Emotron 21.04.09
7.1.3 Important master programs (factory setting)
The following master programs are provided:
LIFT7SZ.KOM/LIFT7SZ.UPD receive date 2003-05-24, supports all '40 MHz' devices after the MNo.
193000 (AUDYxxN and TUDYxxN) in the DSV 544x-Lift series. It always suffices for all 'normal'
geared winches (e.g. worm). The assignments list corresponds to Figure '7SZ' in the instructions.
LIFT7SZ.KOM (or the update file LIFT7SZ.UPD) after 2002-05-23, 'default' is present on the old
function with respect to output 'A0'. After MNo. 217000 (TUDYxxN), a switchover can now also be
made to the new function. If parameter 'F29' is switched over on older firmware, output 'A0' does not
function (it always remains 'low' in association with 'AUDYxxN'. 'Quick menu' (internal FU-Control
after March 2002) or LIFT_E.CNF ('Default' application of EmoSoftLift) suffices for the setting of
systems under LIFT7SZ.KOM. Emergency evacuation (input 'E1') is supported.
xxxxx7TZ.KOM/xxxxx7TZ.UPD receives date 2007-10-29, supports all '40 MHz' devices after the
MNo.: 193000 (AUDYxxN and TUDYxxN) and also new ’50 MHz’-boards (working with TUDXxxN) in
the DSV 544x-Lift series. It is recommended for all higher quality geared winches. Such winches
include all epicyclical gears or hypoid gears with asynchronous motors and belt gears and worms
with higher gear ratios (all gears with high efficiencies). Separate I-gains (as with gearless drives)
are possible here in contrast to LIFT7SZ.KOM/LIFT7SZ.UPD, which considerably improves running
comfort during 'start' and 'stopping'. The assignments and functions otherwise correspond to older
LIFT7SZ. The new function of the 'A0'signal is set in the factory for TUDYxxN in this case (if used
under AUDYxxN, then you must reset the 'F29' parameter back to '242' so that 'A0' functions
'normally' again.
Master programs for asynchronous gearless or synchronous motors ('50 MHz' devices) are all
customised. Such lift programs include, for example, GAF58NEU.KOM/GAF58NEU.UPD (a factory
setting for asynchronous gearless Type 'Klose'), GAxx2567.KOM/GAxx2567.UPD (factory settings
for all Blocher gearless), SMxxx7TZ.KOM (factory settings for Ziehl-Abegg gearless),
WSGxxxxx.KOM (factory setting for Wittur-SAD gearless winches), EPM7-xxx.KOM (factory setting
for Alpha synchronous motors), and still for NINGB256.KOM/NINGB256.UPD (factory setting for
Ningbo Motors China). All of these files have '7TZ' assignments, whereby the high interpolation
(typically 256 x 4 x 2048 = 2097152), needed for gearless technology, is provided by the '50 MHz'
firmware.
If the attachment DCP, ACP or 10SZ is used in the program name, (e.g. NINGBDCP…. or
GAF58DCP….), then the '10SZ' assignments are valid (a gearless drive with a bus system, e.g.
DCP_01, etc. is being used.). Gearless drives are normally pre-set; you should contact us before
changing certain parameters. Only speed, ramps and, in some cases, gains 'k' and 'F7' (see
parameter list) are normally to be changed. Please pay attention with respect to synchronous
motors that 'primary initialisations' may need to be performed to determine the rotor position 'E6E'.
The 'first steps' for synchronous motors will be explained later (see PowerPoint-animation or mpeg-
video of your EmoSoftLift-CD).
List of all factory-settings: For most winches we provide ’ready-tuned’ programs. Over internet or
in the root of our customer-CD you will find the file ’gearlist.htm’ and/or ’gearlist.pdf’, which is very
helpful to decide for correct files for your application. For more details please contact us direct.