Emotron CDU/CDX 48-026 [8/82] Emotron dsv 5445 5444

Emotron CDU/CDX 48-008 [8/82] Emotron dsv 5445 5444
EMOTRON DSV 5445/5444
Page 8
Emotron 21.04.09
3 Technical data
3.1 Type code DSV - LIFT:
DSV 54 45 - 40 - 70 / 400
Nominal supply voltage [V]
Dynamic output current (I
dyn
Nominal device current [A]
Development status
Type key
3.2 Electrical data
Typical input voltage range: 3 × 400V ±10 % TT, TN system
(3 x 500V .+5%/-15%) TT, TN system (option)
(1/3 x 230V ±10 % ) TT, TN system (option)
Other connection voltages and/or IT system on
request
Power mains frequency: 50...60 Hz ± 5 %
Control voltage for fans from 80A-DSV: 230V +5, -15 %
Control voltage PLC level: +24V ±15 %
Typical power factor >0,97
Output voltage: 3 × 0...(network input voltage – 20V)
Output frequency: 0...400 Hz
Pulse frequency adjustable: 2.5...15 kHz (typ. 10 kHz, BGR 5 > 200A: 5kHz)
Typical du/dt: < 1 kV/µs (with AddOn filter)
Dynamic output current (I
dyn
): 150 % (200% BGR 1 10A)
Duty cycle at 10 kHz (12 kHz) PWM: 65 % (50%)
Control range (2…64.pole motors): 1:32000
Encoder interpolation for !Vpp up to 256-times for 2048 pulses per revolution
Fixed speeds: 6
Speed thresholds: 3
Protection class: IP 20
Ambient temperature: 0 ... 40 °C
Storage temperature -20…70 °C
Humidity rating E to DIN 40040
Power reduction from 40 °C by 1.5 % per 1 C° (maximum up to 55 °C)
Installation altitude up to 1000m, thereafter power reduction 6% per 1000m

Содержание

Скачать