Emotron CDU/CDX 48-026 [41/82] Emotron dsv 5445 5444

Emotron CDU/CDX 48-037 [41/82] Emotron dsv 5445 5444
EMOTRON DSV 5445/5444
21.04.09 Emotron
Page 41
Adr. Variable in FU-Control Remarks TUDY/X TUDZ
E24 Braking delay
V Time after stopping V = 0 m/s, the motor continues to
be magnetised until the brake has closed
mechanically, value range: 1 - 4000 ms
500 250
E26 OFF delay
V Delay time for signals A0 and A7 for motor
demagnetisation before motor contactors are open.
Value range: 1 - 4000 ms
125 125
E28 Start delay
V Time between the mechanical opening of the brake
and start up. Value range: 1 - 4000 ms, use the
smallest possible value for this with gearless, but do
not drive against the brake.
250
125
E2A preselection overload
V This function depends on the actually program-
version. Please ask us for details. For example in 40-
MHz this adjust UPS/battery –current (using input E1)
100 60
E2C load-sensing-offset V Adjusts analogue setpoint only in +/-10V mode 0 0
E2E load-sensing hyst. V Mask-out of interferences regarding 0V-zone (5mV=1) 3 0
E3C Schmitt flag /digital flag
V Determines the mode (digital=255 or analogue=0)
255 255
E3E JP3 flag TTL+HTL=255
V
Set encoder type (sinusoidal = 0, TTL or HTL = 255) 0 0
E40 Suspension
V Number of pulleys, 1 for 1:1, 2 for 2:1
Value range: 1 - 4
1 2
E42 Transmission to ...
V
37
1
E44 ... Number of cycles
V
Gear translation ration according to gear rating
plate information. Enter "1" for gearless, in the typical
factory setting, means, e.g. 54 : 4 = 18.88 : 1
(translation ratios can only be represented by a
fraction in the DSV system). Value range: 1 - 500 (or
1 - 10).
1 1
E46 Drive wheel diameter
V Effective drive wheel diameter in 'mm'.
Value range: 25 -1.000 mm (for gearless max. 625)
600
400
E48 Calculation? Yes=255 V
Yes = 255, no = 0. If 255 is entered here, then
parameters F10, F21 and F22 are calculated
automatically and thus also the travelling speed and
approach from your system data. E48 = '255' is
urgently recommended. (Attention: The specification
of '0' possibly leads to unexpected speeds and runs!)
255 255
E4A Encoder increments
V Set encoder pulses per revolution (see also variable
0E3E), following are permitted: 500, 1024, 2048,
2500, 4096 pulses for '40 MHz' and 1024 and 2048
for '50 MHz' encoder PPRs.
FU-Control: Entry of 2500, 4096 can cause a
"Parameter error" fault. In this case, please set
parameter F24 from 2 to 1 and save.
1024
2048
E4C Starting jerk speed
V Starting jerk speed to overcome the static friction
during start. The speed is dependent upon the
selected starting jerk time. A long time requires also a
higher value of 0E4C.
TTL encodes sometimes possess insufficient
resolution; set a higher speed, e.g. min. 0.005 m/s,
value range : 0.001 - 0.020m/s (gearless under
0.001).
0.003
0.001

Содержание