Icom IC-M604A [38/68] D test call

Icom IC-M604A [38/68] D test call
32
6
DSC OPERATION
Transmitting DSC Calls (Continued)
D Test call
Testing on the exclusive DSC distress and safety calling
channels should be avoided as much as possible by using
other methods. When testing on the distress/safety channel is
unavoidable, it should be indicated that these are test trans-
missions.
Normally the test call would require no further communica-
tions between the two stations involved.
q Enter “6GUV%CNN in the DSC menu.
w Rotate [SELECTOR] to select a desired pre-programmed
Individual address or /CPWCN +PRWV, then push
[ENT].
The ID code for the individual can be set fi rst. (p. 16)
When “
/CPWCN+PRWV” is selected, push the keypad keys
to set the 9 digit MMSI ID code for the individual you wish to
call.
e After step w, “6GUV%CNN4GCF[ appears.
r Push [ENT] to transmit the Test call.
If Channel 70 is busy, the transceiver stands by until the channel
becomes clear.
t After the Test call has been transmitted, the display auto-
matically returns to the previous screen (before you en-
tered the DSC menu).
&5%/GPW 6GUV%CNN