Metabo P 4000 S [13/62] Installing the hydromat hwa only

Metabo P 4000 S [13/62] Installing the hydromat hwa only
13
ENGLISH
"Technical Specifications"). Com-
pletely unroll cable reels.
Do not buckle, squeeze, drag or
drive over power cable and exten-
sion cables; protect from sharp
e
dges.
Pl
ace extension cable so that it can
not get into the fluid to be pumped.
Unplug:
p
rior to all servicing;
w
hen persons are in the swim-
ming pool or garden pond.
A
Danger by pump failures!
If
you notice transport damage while
unpacking, notify your supplier
immediately. Do not operate the
pump!
Be
fore each use check the pump,
especially the power cable and plug
for possible damage. Risk of fatal
electric shock!
A da
maged pump must be work-
manlike repaired before it can be
u
sed again.
D
o not attempt to repair the pump
yourself! Only trained specialists are
permitted to service or repair pumps
or pressure vessels.
A
Caution!
To avoid water damage, e.g.
flooded rooms, caused by pump mal-
functions or defects:
provide for suitable safety measures
such as the following:
alarm or
collection tank with monitoring.
The manufacturer is not liable for any
da
mage caused by:
improper use of the pump;
overloading of the pump through
co
ntinous operation;
failure to operate and store the
p
ump in a frost-free environment;
unauthorised modification of the
p
ump (repairs to electrical equip-
ment may only be carried out by
q
ualified electricians!);
use of spare parts which have not
b
een tested and approved by the
manufacturer; or
use of unsuitable installation materi-
als (fittings, connection lines etc.).
Suitable installation materials:
pressure-resistant
(min. 10 bar)
heat-resistant (min. 100°C).
The pump is easily assembled and con-
nected.
If in doubt, contact your specialist sup-
plier or a qualified electrician.
5.1 Installing the Hydromat
(HWA only)
3
Note:
Before initial operation the Hydro-
mat must be installed (illustration
according to version).
1. Check to see that the pump is
turned off and the power cord plug
(18) is unplugged.
2. Turn adaptor (16) onto the dis-
charge port of the pump.
3. Place Hydromat (17) on the adaptor
and secure with the union nut.
4. Adjust Hydromat position so that the
co
ntrol panel is easily accessible.
5. Plug power cord plug of pump (18)
in the Hydromat's cable socket (19).
5.2 Installation
The pump must be placed on a
plane and level surface, suitable of
bearing the weight of the pump fully
filled with water.
To avoid
vibrations the pump should
be placed on an elastic base.
The
installation location should be
well vented and protected from
atmospheric exposure.
When operated at garden ponds
and pools the pump must be set up
safe against flooding and safe-
garded against falling into the water.
An
y additional legal requirements
are to be observed.
5.3 Connecting the Suction
Line
3
Note:
Possibly further accessories may
be
required for connection (see "Availa-
ble Accessories").
A
Caution!
The suction line needs to be
insta
lled in such manner that it does
not exert mechanical force or distor-
tion to the pump.
A
Caution!
When pumping contaminated
flu
ids install a suction strainer to pro-
tect the pump from sand and dirt.
3
Note:
A check valve is recommended to
prevent water backflow when the pump
is turned off.
All screw fittings must be sealed
with thread sealing tape; leaks
cause the priming of air, which
reduces or completely prevents the
priming of water.
Th
e suction line should have an
inner diameter of 1" (25 mm) mini-
mum and must be kink, pressure,
and vacuum
resistent.
Ke
ep suction line as short as practi-
cal, as with increasing length the
p
ump capacity is reduced.
The
suction line should ascend
towards the pump to prevent air
locks.
A sufficient water supply must be
ensured, the foot valve at the end of
the suction line must be submerged
in water at all times.
5.4 Discharge Port
3
Note:
Possibly further accessories may
be
required for connection (see "Availa-
ble Accessories").
A
Caution!
The discharge (or pressure)
lin
e needs to be installed in such
manner that it does not exert mechan-
ical force or distortion to
the pump.
Al
l screw fittings should be sealed
with thread sealing tape to prevent
leakage.
All parts of the pressure line must be
resistant to internal pressure.
All
parts of the pressure line must be
installed in a workmanlike manner.
A
Danger!
Improper installation and use
of
parts not resistant to internal pres-
sure can cause the pressure line to
br
eak during operation. Risk of per-
sonal injury by liquid spurting from
the
line under high pressure!
5. Prior to Operation
16
17
1819

Содержание