Daikin EKHTSU260AC [100/292] A for leaving water temperature and or room temperature see leaving water temperature control setting 8 00

Daikin EKHTSU260AC [100/292] A for leaving water temperature and or room temperature see leaving water temperature control setting 8 00
Field Setting ESIE09-08B
88 Test Operation
Notes : By default space heating based on temperature set point (method 1) is enabled, so only
temperature shifts are possible (no ON/OFF instruction). The system keeps operating.
Advantage of this method is that you can simply switch off the space heating operation by
p
u
shing the y button without disabling the automatic domestic hot water storage operation
(e.g. during summertime when no space heating is required).
In the following tables both methods on how to interpret the schedule timer are shown.
(a) For leaving water temperature and/or room t
emperature see leaving wate
r temperature
control (setting 8-00).
Operation example: Schedule timer based on temperature set points.
When setback function is enabled, the setback operation will have priority over the scheduled
a
c
tion in the schedule timer setting 2.
Remark: Room temperatu
r
e and leaving water temperature have no fix relationship. Both
temperatures can be adjusted independently.
Method 1 Space heating based on temperature set point
(a)
During operation During schedule timer operation the operation LED is lit continuously.
When pushing the y button The schedule timer for space heating will stop and will not start aga
in.
The controller will be switched off (operation LED will stop working).
However, the schedule timer icon will stay di
splayed which means that the
domestic water heating stays enabled.
When pushing the r/p button The schedule timer for space heating and do
mestic water heating along with
the quiet mode will be stopped and will not start again.
The schedule timer icon will not be displayed anymore.
1 Schedule timer
2 Setback function
3 When both setback function and schedule timer are enabled
A Setback function
t Time
T
Temperature set point
Room temperature
Leaving water temperature
T
t
6:30 9:00
16:00
0:30
19
19°C
19
19°C
19
19°C
22
22°C
21
21°C
62
62°C
62
62°C
62
62°C
65
65°C
64
64°C
62°C
19°C19°C19°C
22°C
21°C
62°C62°C
65°C
64°C
0:30
1
T
t
18
18°C
57
57°C
57°C
18°C
A
5:00
5:00
23:00
23:00
5:0023:00
2
T
t
5:00 9:00
16:00
23:00
19
19°C
18
18°C
19
19°C
22
22°C
21
21°C
62
62°C
60
60°C
62
62°C
65
65°C
64
64°C
60°C
19°C
18°C
19°C
22°C
21°C
62°C62°C
19
19°C
62
62°C
19°C
62°C
19
19°C
62
62°C
19°C
62°C
19
19°C
62
62°C
19°C
62°C
65°C
64°C
6:30
3
57
57°C
57°C
60
60°C
60°C

Содержание

Скачать