Nec MultiSync V554 PG (Protective Glass) Списки команд RS-232 онлайн [130/141] 314779
![Nec MultiSync V554 PG (Protective Glass) Списки команд RS-232 онлайн [130/141] 314779](/views2/1375342/page130/bg82.png)
(130/139)
CNH: Current log data Number (High byte)
CNL: Current log data Number (Low byte)
'0','0','0','1' -'F','F','F','F' (30h, 30h, 30h, 31h - 46h, 46h, 46h, 46h) :1 - 65535
Data(0)-Data(18): Data of Proof of Play
------------------------------------------
※
Log Data of Proof of Play : Data(0)-Data(18)
Data(0): Check INPUT PITURE
※
Same as VCP(Page11 06H Input source) reply parameter.
Refer to Item “INPUT” on page 41.
Data(1)-Data(4) : Check Input Signal
'0'-'0'-'0'-'0'-'0'-'0'-'0'-'0' (30h,30h,30h,30h,30h,30h,30h,30h):No signal
'F'-'F'-'F'-'F'-'F'-'F'-'F'-'F' (46h,46h,46h,46h,46h,46h,46h,46h):Invalid signal
'*'-'*'-'*'-'*'-'*'-'*'-'*'-'*' (**h,**h,**h,**h,**h,**h,**h,**h):Input signal
Ex ) 1920 x 1080
'0'-'7'-'8'-'0'-'0'-'4'-'3'-'8' : 1920(0768h) x 1080(0438h)
Data(5) : Check INPUT AUDIO
※
Same as VCP(Page2 2EH Select Sound Input) reply parameter.
Refer to Item “AUDIO INPUT” on page 33.
Data(6) : Check with or without Audio
'0'-'0'(30h,30h): Audio in
'0'-'1'(30h,31h): No Audio in
'0'-'2'(30h,32h): N/A
Data(7) : Check status (Picture)
'0'-'0'(30h,30h): Normal Picture
'0'-'1'(30h,31h): No Picture
Data(8) : Check status (Audio)
'0'-'0'(30h,30h): Normal Audio
'0'-'1'(30h,31h): No Audio
Data(9)-Data(10) : Year
'*'-'*'-'*'-'*' (**h,**h,**h,**h):0
~
65535(0000h
~
FFFFh)
Ex ) 2014
'0'-'7'-'D'-'E' : 2014(07DEh)
Data(11) : month
'0'-'1' (30h,31h): January
'0'-'2' (30h,31h): February
|
'0'-'B' (30h,31h): November
'0'-'C' (30h,31h): December
Data(12) : day
'*'-'*' (**h,**h):1
~
31(01h
~
1Fh)
Date(13) : hour
'*'-'*' (**h,**h):0
~
23(00h
~
17h)
Date(14) :min
'*'-'*' (**h,**h):0
~
59(00h
~
3Bh)
Data(15) : sec
'*'-'*' (**h,**h):0
~
59(00h
~
3Bh)
Data(16) : Extention parameter
'0'-'0'(30h,30h): Normal Proof of Play event
'0'-'1'(30h,31h): Proof of Play event is “last power on time” *1)
'0'-'2'(30h,32h): Reserved
'1'-'0'(31h,30h): MEDIA PALYER is stop
'1'-'1'(31h,31h): MEDIA PLAYER is start
'1'-'2'(31h,32h): MEDIA PLAYER is pause
'1'-'3'(31h,33h): MEDIA PLAYER error occur
'1'-'4'(31h,34h) – '1'-'F'(31h,46h): Reserved
'2'-'0'(32h,30h): Contents Copy from USB
'2'-'1'(32h,31h): Contents Copy form network folder
'2'-'2'(32h,32h) – '2'-'F'(32h,46h): Reserved
Содержание
- External control nec lcd monitor 1
- Rev g4 index 1
- Connectors and wiring 4
- I application 4
- Ii preparation 4
- Rs 232c remote control 4
- Lan control 5
- Communication parameter 6
- Communication timing 6
- Iii communication specification 6
- Lan control 6
- Rs 232c remote control 6
- Command 7
- Command reply 7
- Communication format 7
- Get parameter 7
- Get parameter reply 7
- Monitor controller 7
- Save current setting command 7
- Save current setting command reply 7
- Set parameter 7
- Header block format fixed length 8
- Message block format 10
- Address 12
- Check code 12
- Delimiter 12
- Header message check code bcc 12
- Message 12
- Message length stx op code 12
- Op code set value etx 12
- Soh reserved destination 12
- Source address 12
- Delimiter 13
- Get current parameter from a monitor 14
- Message type 14
- Get parameter reply 15
- Set parameter 17
- Set parameter reply 18
- Commands 19
- Save current settings 19
- Get timing report and timing reply 20
- Null message 21
- How to change the backlight setting 22
- Iv control commands 22
- Typical procedure example 22
- How to read the measurement value of the built in temperature sensors 25
- Brigtness 28
- Operation code op code table 28
- Picture 28
- Adjust 1 29
- Aspect 30
- Advanced 31
- Rotation 31
- Audio delay 32
- Balance 32
- Equlizer 32
- Schdule 32
- Schedule 32
- Active picture 33
- Input select 33
- Multi input 33
- Picture position 33
- Custom detect 34
- Rotate 2 34
- Text ticker 34
- Equalizer 1 35
- Terminal setting 35
- Multi display 36
- Osd position 36
- Tile matrix 36
- Display protection 37
- Fan control 37
- Control 38
- Heat status 38
- Ir lock setting 38
- Motion 38
- Power on delay 38
- Screen saver 38
- Key lock setting 39
- Auto dimming 40
- Backlight 40
- Backlight setting 40
- Human sensing 40
- Input select 40
- Room light sensing 40
- Volume 40
- Internal pc 41
- Option 41
- Power indicator 41
- Compute module 42
- Monitor information 42
- Service menu 42
- System 42
- Picture 44
- Power control procedure 46
- Power status read 46
- Power control 48
- Asset data read and write 50
- Asset data read request and reply 50
- Asset data write 51
- Date time read 53
- Date time read and write 53
- Date time write 55
- The controller requests the monitor to write date time 55
- This command is used in order to write the setting of the date time 55
- Schedule read 58
- Schedule read and write 58
- Schedule write 62
- Holiday read 70
- Holiday read and write 70
- Holiday write 72
- The controller requests the monitor to write date time 72
- This command is used in order to write the setting of holiday 72
- Weekend read 75
- Weekend read and write 75
- The controller requests the monitor to write the setting of weekend 77
- This command is used in order to write the setting of weekend 77
- Weekend write 77
- Self diagnosis 79
- Self diagnosis status read 79
- Serial no model name read 81
- Serial no read 81
- Model name read 83
- Security lock 85
- Security lock control 85
- Direct tv chanel read reply 87
- Direct tv chanel read write 87
- Stx c 3 2 c majorch minorch etx 87
- Direct tv chanel write reply 88
- Stx c 3 2 d majorch minorch etx 88
- Daylight saving read 89
- Daylight saving read write 89
- Daylight saving write 91
- Firmware version 93
- Firmware version read 93
- Auto id 95
- Auto id execute 95
- Auto id complete 96
- Auto id reset 97
- Input name 98
- Input name read 98
- Input name write 100
- Input name reset 102
- Auto tile matrix 103
- Auto tile matrix execute 103
- Auto tile matrix complete 105
- Auto tile matrix monitors read 106
- Auto tile matrix monitors write 107
- Auto tile matrix reset 108
- Power save mode 109
- Power save mode read 109
- Power save mode write 111
- Auto power save time read 113
- Auto power save time write 114
- Auto standby time read 115
- Auto standby time write 116
- Setting copy 117
- Setting copy read 117
- Setting copy write 119
- Setting copy start 121
- Security enable 122
- Security enable read 122
- Security enable write 123
- Lan mac address 125
- Lan mac address read 125
- Proof of play 127
- Set proof of play operation mode 127
- Get proof of play current 129
- Get proof of play status 132
- Get proof of play number to number 134
- Setting lock control 136
- Setting lock of compute module 136
- Emergency contents 138
- Emergency contents display 138
- Emergency contents delete 140
- All data are subject to change without notice 141
Похожие устройства
- Nec MultiSync V554 PG (Protective Glass) Руководство пользователя
- Nec MultiSync V484 PG (Protective Glass) Энергетическая наклейка
- Nec MultiSync V484 PG (Protective Glass) Списки команд RS-232
- Nec MultiSync V484 PG (Protective Glass) Руководство пользователя
- Nec V404 PG (Protective Glass) Энергетическая наклейка
- Nec V404 PG (Protective Glass) Списки команд RS-232
- Nec V404 PG (Protective Glass) Руководство пользователя
- Nec MultiSync P554 PG (Protective Glass) Энергетическая наклейка
- Nec MultiSync P554 PG (Protective Glass) Списки команд RS-232
- Nec MultiSync P554 PG (Protective Glass) Руководство пользователя
- Nec MultiSync P484 PG (Protective Glass) Энергетическая наклейка
- Nec MultiSync P484 PG (Protective Glass) Списки команд RS-232
- Nec MultiSync P484 PG (Protective Glass) Руководство пользователя
- Nec MultiSync P404 PG (Protective Glass) Энергетическая наклейка
- Nec MultiSync P404 PG (Protective Glass) Списки команд RS-232
- Nec MultiSync P404 PG (Protective Glass) Руководство пользователя
- Nec MultiSync P554 SST (ShadowSense) Энергетическая наклейка
- Nec MultiSync P554 SST (ShadowSense) Списки команд RS-232
- Nec MultiSync P554 SST (ShadowSense) Руководство пользователя
- Nec MultiSync P484 SST (ShadowSense) Энергетическая наклейка