Hyundai Robex 170W-7 [162/174] Charging circuit

Hyundai Robex 170W-7 [162/174] Charging circuit
CHECK POINT
4-9
3. CHARGING CIRCUIT
When the starter is activated and the engine is started, the operator releases the key switch to the ON
position.
Charging current generated by operating alternator flows into the battery through the battery relay
(CR-1).
The current also flows from alternator to each electrical component and controller through the fuse box.
OPERATING FLOW
Warning flow
Alternator "I" terminal I/conn CN-2(13) CPU alternator level CN-51(9)
Cluster charging warning lamp(Via serial interface)
Charging flow
Alternator "B
+
" terminal Battery relay(M8) Battery(+) terminal
Fusible link CN-60 Fuse box
1)
2)
(1)
(2)
GND : Ground
Engine Start switch Check point
Voltage
Run ON
- GND(Battery voltage)
- GND(Battery relay)
- GND(Alternator B
+
terminal)
- GND(Alternator I terminal)
- GND(CPU)
20~30
V