Daikin FXSQ80P7VEB [206/370] Remote controller service mode

Daikin RTSYQ16PA [206/370] Remote controller service mode
Troubleshooting by Remote Controller SiBE311209
197 Service Diagnosis
3.4 Remote Controller Service Mode
Operating the CHECK/TEST button on the remote controller will make it possible to obtain
"service data" and change "service setting" while in service mode.
How to Enter the
Service Mode
Service Mode
Operation
Method
1. Select the mode No.
Select the desired item from the Service menu, and then press Menu/Enter button.
2. Select the Item 2.
Select the desired Unit No. using the
S
/
T
(Up/Down) buttons. The corresponding data will be
displayed.
For details, refer to the table in next page.
Normal status
Enters inspection mode from normal
status when the INSPECTION/TEST
button is pressed.
1 Press INSPECTION/TEST button.
If no button is pressed
for 1 minute, equipment
returns to normal status.
If no button is pressed
for 1 minute, equipment
returns to normal status.
When MODE selector
button is pressed or no
button is pressed for 1
minute, equipment
returns to normal status.
3
Press
MODE
selector
button.
5 Press MODE selector button.
Basic screen Field setting mode
Service mode
Press and hold Cancel button for 4 seconds or more.
Press and hold Cancel button for 4 seconds or more.

Содержание

Скачать