Daikin REYQ14PY1 [31/438] Specifications

Daikin REYQ20PY1 [31/438] Specifications
Specifications Si37-701
20 Specifications
Notes:
1 Indoor temp. : 27°CDB, 19.5°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5m, level
difference : 0m.
2 Indoor temp. : 27°CDB, 19.0°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5m, level
difference : 0m.
3 Indoor temp. : 20°CDB / outdoor temp. : 7°CDB, 6°CWB / Equivalent piping length : 7.5m, level difference
: 0m.
4 The units with anti-corrosion treatment will be available as standard. Please specify the suffix “E” as
REYQ8PY1E.
Model Name (Combination Unit) REYQ46PY1(E) REYQ48PY1(E)
Model Name (Independent Unit) REMQ14PY1(E)+REMQ16PY1(E)+REMQ16PY1(E) REMQ16PY1(E)+REMQ16PY1(E)+REMQ16PY1(E)
1 Cooling Capacity (19.5°CWB)
kcal / h 113,000 117,000
Btu / h 447,000 464,000
kW 131 136
2 Cooling Capacity (19.0°CWB) kW 130 135
3 Heating Capacity
kcal / h 124,000 129,000
Btu / h 495,000 512,000
kW 145 150
Casing Color
Y1 Type Ivory White 5Y7.5/1 Ivory White 5Y7.5/1
Y1E Type Light Camel 2.5Y6.5/1.5 Light Camel 2.5Y6.5/1.5
Dimensions: (H×W×D) mm 1680×1240×765+1680×1240×765+1680×1240×765 1680×1240×765+1680×1240×765+1680×1240×765
Heat Exchanger Cross fin coil Cross fin coil
Comp.
Type Hermetically sealed scroll type Hermetically sealed scroll type
Piston Displacement m³/h (13.34+10.53+10.53)×3 (13.34+10.53+10.53)×3
Number of Revolutions r.p.m (6300, 2900, 2900)×3 (6300, 2900, 2900)×3
Motor Output×Number
of Units
kW (3.2+4.5+4.5)×2+(1.9+4.5+4.5)×1 (3.2+4.5+4.5)×3
Starting Method Soft start Soft start
Fan
Type Propellor fan Propellor fan
Motor Output kW (0.35×2)+(0.35×2)×2 (0.35×2)×3
Air Flow Rate
I/s 3,833+3,833+3,833 3,833+3,833+3,833
m³/min 230+230+230 230+230+230
Drive Direct drive Direct drive
Connecting
Pipes
Liquid Pipe
φ
19.1 C1220T (Brazing connection)
φ
19.1 C1220T (Brazing connection)
Suction Gas Pipe
φ
41.3 C1220T (Brazing connection)
φ
41.3 C1220T (Brazing connection)
High and Low Pressure Gas Pipe
φ
34.9 C1220T (Brazing connection)
φ
34.9 C1220T (Brazing connection)
Pressure Equalizer Tube
φ
19.1 C1220T (Brazing connection)
φ
19.1 C1220T (Brazing connection)
Mass (Weight) kg 334+334+334 334+334+334
Safety Devices
High pressure switch, fan driver overload protector,
overcurrent relay, inverter overload protector
High pressure switch, fan driver overload protector,
overcurrent relay, inverter overload protector
Defrost Method Deicer Deicer
Capacity Control % 4~100 4~100
Refrigerant
Refrigerant Name R-410A R-410A
Charge kg 11.7+11.7+11.7 11.7+11.7+11.7
Control Electronic expansion valve Electronic expansion valve
Refrigerator Oil Refer to the nameplate of compressor Refer to the nameplate of compressor
Standard Accessories
Installation manual, Operation manual, Connection pipes,
Cramps
Installation manual, Operation manual, Connection pipes,
Cramps
Drawing No. 4D057817 4D057818
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3412
cfm=m³/min×35.3