Daikin EKHVMYD50ABV1 [19/64] 11 18 17

Daikin EKHVMYD50ABV1 [19/64] 11 18 17
EKHVMRD50+80ABV1 + EKHVMYD50+80ABV1
Daikin Altherma indoor unit
4P404420-1 2015.04
Installation manual
17
EKHVMRD Tank heat meter between tank and indoor unit EKHVMRD Tank heat meter on tapping side
1 Outdoor unit 14 Flow measuring unit of space
heat meter
(eld supply)
2 Indoor unit
3 Indoor unit refrigerant
stop valves
15 Temperature sensor space
heat meter
(eld supply)
4 Electronic expansion
valve
5 Refrigerant heat
exchanger
16 Space heating applications
6 Heating heat
exchanger
17 Field piping
18 Tank billing kit (optional) in
case the domestic hot water
tank is mounted on top of the
indoor unit
OR
Floor mounted tank kit
(optional) in case the
domestic hot water tank is
installed on the oor next to
the indoor unit
7 Pump
8 Motorized 3-way valve
(optional)
9 Domestic hot water
tank (optional)
10 Compressor
11 Shut-off valve
12 Flow measuring unit of
heat meter
(eld supply)
13 Temperature sensors
heat meter
(eld supply)
4 45 6 7 91318 17
13 12
23
3
1
M
10
11 11
18 17
14
16
15
8
1 Outdoor unit 11 Shut-off valve
2 Indoor unit 12 Flow measuring unit of heat
meter (eld supply)
3 Indoor unit refrigerant
stop valves
4 Electronic expansion
valve
13 Temperature sensors heat
meter (eld supply)
5 Refrigerant heat
exchanger
14 Flow measuring unit of space
heat meter (eld supply)
6 Heating heat
exchanger
15 Temperature sensor space
heat meter (eld supply)
7 Pump 16 Space heating applications
8 Motorized 3-way valve
(optional)
9 Domestic hot water
tank (optional)
10 Compressor
4 45 6 7 9 13
13
1223
3
1
M
10
11 11
14
16
15
8

Содержание