9.5. Detailed description
For a summary of all eld settings refer to "9.9. Field setting table" on
page 49.
[0] Remote control setup
[0-00] User permission level
The remote controller can be programmed to make certain
buttons and functions unavailable for the user. There are 2
permission levels dened. Both levels (level 2 and level 3) are
basically the same, the only difference is that for level 3 no water
temperature settings are possible (see table below).
By default no level is dened so all buttons and functions are
operable.
The actual permission level is determined by eld setting. For
permission level 2, set eld setting [0-00] to 2, for permission
level 3, set eld setting [0-00] to 3.
Once the eld setting is set, the chosen permission level is not
yet active. Enabling the selected permission level is done by
simultaneously pressing buttons and immediately
followed by simultaneously pressing buttons and , and
keeping all 4 buttons pressed for at least 5 seconds. Note that
no indication on the remote controller is given. After the
procedure the blocked buttons will not be available anymore.
Deactivating the selected permission level is done in the same
way.
[0-01] Room temperature compensation value
If needed, it is possible to adjust some thermistor value of the
unit by a correction value. This can be used as countermeasure
for thermistor tolerances or capacity shortage.
The compensated temperature (= measured temperature plus
compensation value) is then used for controlling the system and
will be displayed in the temperature read-out mode. See also
"[9] Automatic temperature compensation" on page 39 for
compensation values for leaving water temperature and
domestic hot water temperature.
[0-02] Setting not available
[0-03] Status: denes whether the ON/OFF instruction can be
used in the schedule timer for space heating.
Refer to the operation manual for details how to program the
schedule timer.
The schedule timer for space heating can be programmed in
2 different ways: based on the temperature set point (both
leaving water temperature and room temperature) and based on
the ON/OFF instruction.
In the following tables both methods on how to interpret the schedule
timer are shown.
Operation example: Schedule timer based on temperature set
points.
When setback function is enabled, the setback operation will have
priority over the scheduled action in the schedule timer.
Permission
level 2 level 3
Operation ON/OFF Operable Operable
Domestic water heating operation ON/
OFF
Operable Operable
Setting the leaving water temperature Operable
Setting the room temperature Operable Operable
Quiet mode ON/OFF ——
Weather dependent set point operation
ON/OFF
Operable
Setting the clock ——
Programming the schedule timer ——
Schedule timer operation ON/OFF Operable Operable
Field settings ——
Error code display Operable Operable
Test operation ——
NOTE
By default space heating based on temperature set
point (method 1) is enabled, so only temperature shifts
are possible (no ON/OFF instruction).
Advantage of this method is that you can simply switch
off the space heating operation by pushing the
button without disabling the automatic domestic hot
water storage operation (e.g. during summertime when
no space heating is required).
Method 1 Space heating based on temperature set point
(a)
(a) For leaving water temperature and/or room temperature
During operation During schedule timer operation the operation LED is lit
continuously.
When pushing
the button
The schedule timer for space heating will stop and will
not start again.
The controller will be switched off (operation LED will
stop working).
However, the schedule timer icon will stay displayed
which means that the domestic water heating stays
enabled.
When pushing
the / button
The schedule timer for space heating and domestic
water heating along with the quiet mode will be stopped
and will not start again.
The schedule timer icon will not be displayed anymore.
1 Schedule timer
2 Setback function
3 When both setback function and schedule timer are enabled
A Setback function
t Time
T Temperature set point
Room temperature
Leaving water temperature
T
t
6:30 9:00
16:00
0:30
19
19
°C 19
19
°C 19
19
°C
22
22
°C
21
21
°C
62
62
°C 62
62
°C 62
62
°C
65
65
°C
64
64
°C
62°C
19°C19°C19°C
22°C
21°C
62°C62°C
65°C
64°C
0:30
1
T
t
18
18
°C
57
57
°C57°C
18°C
A
5:00
5:00
23:00
23:00
5:0023:00
2
T
t
5:00 9:00
16:00
23:00
19
19
°C
18
18
°C
19
19
°C
22
22
°C
21
21
°C
62
62
°C
60
60
°C
62
62
°C
65
65
°C
64
64
°C
60°C
19°C
18°C
19°C
22°C
21°C
62°C62°C
19
19
°C
62
62
°C
19°C
62°C
19
19
°C
62
62
°C
19°C
62°C
19
19
°C
62
62
°C
19°C
62°C
65°C
64°C
6:30
3
57
57
°C57°C
60
60
°C60°C

Содержание

Скачать