Daikin EKHVMYD50ABV1 [60/64] Nit specifications

Daikin EKHVMYD50ABV1 [60/64] Nit specifications
Installation manual
58
EKHVMRD50+80ABV1 + EKHVMYD50+80ABV1
Daikin Altherma indoor unit
4P404420-1 2015.04
13. UNIT SPECIFICATIONS
Technical specications
Electrical specications: power supply
Electrical specications: multi tenant power supply
EKHVMRD50ABV1 EKHVMRD80ABV1 EKHVMYD50ABV1 EKHVMYD80ABV1
Nominal capacity (heating)
(kW)
5.6 9 5.6 9
Nominal capacity (cooling)
(kW)
—— 58
Casing material Pre-coated sheet metal
Dimensions HxWxD
(mm)
705x600x695
Weight
with packaging
(kg)
110.8 100.8 115.8 115.8
without packaging
(kg)
92 92 107 107
Water connections
water inlet/outlet G 1" (female)
water inlet/outlet
material
brass
piping diameter
(inch)
1
maximum working
pressure
(bar)
4
Refrigerant connections
discharge side diameter
(mm)
12.7
suction side diameter
(mm)
15.9
liquid side diameter
(mm)
9.52
Heating water system
volume
(l)
20~200
Refrigerant type R134a
Pump
type DC motor
no. of speed inverter controlled
Sound pressure level
(a)
(dBa)
40 42 40 42
Pressure relief valve water
circuit
(bar)
3
Operation range - water
side (heating)
(°C)
25~80
Operation range - water
side (cooling)
(°C)
5~20
Operation range - outdoor
space heating
(°C)
20~20
domestic hot water
(°C)
20~35
Operation range - indoor
Ambient temperature
(°C)
5~30
(a) Sound pressure level is less than 70 dB(A).
Water conditions: entering water 55°C/leaving water 65°C. For more information, see data book.
EKHVMRD50ABV1 EKHVMRD80ABV1 EKHVMYD50ABV1 EKHVMYD80ABV1
Phase 1N~
Frequency
(Hz)
50
Voltage range
minimum
(V)
220
maximum
(V)
240
Voltage tolerance 10%/+6%
Maximum running current
(A)
16.5
Recommended eld fuse
(A)
20
EKHVMRD50ABV1 EKHVMRD80ABV1 EKHVMYD50ABV1 EKHVMYD80ABV1
Phase 1N~
Frequency
(Hz)
50
Voltage
(V)
24
Voltage tolerance 20%/+20%
Maximum running current
(A)
1
Recommended eld fuse
(A)
3.15