Daikin EKHVMYD50ABV1 [55/64] Important information regarding the refrigerant

Daikin EKHVMYD50ABV1 [55/64] Important information regarding the refrigerant
EKHVMRD50+80ABV1 + EKHVMYD50+80ABV1
Daikin Altherma indoor unit
4P404420-1 2015.04
Installation manual
53
Checks
The described checks must be executed at least once a year by
qualied personnel.
1 Pressure relief valve hose
Check that the pressure relief valve hose is positioned
appropriately to drain the water.
2 Water pressure relief valve
Check for correct operation of the pressure relief valve by
turning the red knob on the valve counter-clockwise:
If you do not hear a clacking sound, contact your local dealer.
In case the water keeps running out of the unit, close both
the water inlet and outlet shut-off valves rst and then contact
your local dealer.
3 Indoor unit switch box
Carry out a thorough visual inspection of the switch box and look
for obvious defects such as loose connections or defective
wiring.
4 Water pressure
Check if the water pressure is above 1 bar.
If necessary add water.
5 Water lter
Clean the water lter.
11.2. Important information regarding the refrigerant
used
This product contains uorinated greenhouse gases. Do not vent
gases into the atmosphere.
Refrigerant type: R134a
GWP
(1)
value: 1430
(1)
GWP = global warming potential
NOTE
National implementation of EU regulation on certain
uorinated greenhouse gases may require to provide
the appropriate ofcial national language on the unit.
Therefore, an additional multilingual uorinated
greenhouse gases label is supplied with the unit.
Sticking instructions are illustrated on the backside of
that label.