32
EKHVMRD50+80ABV1 + EKHVMYD50+80ABV1
Daikin Altherma indoor unit
4P404420-1 2015.04
Connection to a benet kWh rate power supply
Electricity companies throughout the world work hard to provide
reliable electric service at competitive prices and are often authorized
to bill clients at benet rates. E.g. time-of-use rates, seasonal rates,
Wärmepumpentarif in Germany and Austria, ...
This equipment allows for connection to such benet rate power
supply delivery systems.
Consult with the electricity company acting as provider at the site
where this equipment is to be installed to know whether it is
appropriate to connect the equipment in one of the benet kWh rate
power supply delivery systems available, if any.
When the equipment is connected to such benet kWh rate power
supply, the electricity company is allowed to:
interrupt power supply to the equipment for certain periods of
time;
demand that the equipment only consumes a limited amount of
electricity during certain periods of time.
The indoor unit is designed to receive an input signal by which the
unit switches into forced off mode. At that moment, the unit
compressors will not operate.
Possible types of benet kWh rate power supply
Possible connections and requirements to connect the equipment to
such power supply are illustrated in the gures below:
WARNING
A benet kWh rate power supply is only possible for the
indoor unit. For compressor reliability reasons it is not
allowed to connect the outdoor unit to such a power supply.
WARNING
For a benet kWh rate power supply like illustrated
below as type 1
During the period that the benet kWh rate is active and
power supply is continuous, then stand-by power
consumption of the inverter PCB is possible.
1 Benet kWh rate power supply box
2 Receiver controlling the signal of the electricity company
3 Benet kWh rate power supply
4 Voltage free contact to indoor unit
5 Normal kWh rate power supply
6 Fuse (eld supply)
In case of benet kWh rate power supply installation,
remove the wiring bridges on X2M before installing the
normal kWh rate power supply.
X3M7 8 X2M8 9X1ML N
LN
2
4
1
5
3
LN
2
1
43
43
LN
2
1
S1S
S1S
S1S
[6-04]=1
LN
2
1
3
LN
2
1
43
4 4
43
L N
LN
2
1
S1S
S1S
S1S
[6-04]=2
X2M10 118 9
6