Daikin EKHVMYD50ABV1 [38/64] Off on on

Daikin EKHVMYD50ABV1 [38/64] Off on on
Installation manual
36
EKHVMRD50+80ABV1 + EKHVMYD50+80ABV1
Daikin Altherma indoor unit
4P404420-1 2015.04
Operation example: Schedule timer based on ON/OFF instruction.
When setback function is enabled, the setback operation will have
priority over the scheduled action in the schedule timer if ON
instruction is active. If OFF instruction is active this will have priority
over the setback function. At any time the OFF instruction will have
the highest priority.
[0-04] Status: denes whether the ON/OFF instruction can be
used in the schedule timer for cooling.
Same as for [0-03] but for cooling schedule timer.
For cooling, no setback function is available.
[1] Automatic storage timing for domestic water heating
In this mode, the indoor unit will deliver hot water to the domestic hot
water tank based on the daily xed pattern. This mode will continue
until storage temperature is reached.
Automatic storage is the advised domestic hot water mode. In this
mode water heats up during the night (when space heating
requirements are lower) until the storage set point. The heated water
is stored in the domestic hot water tank at a higher temperature so it
can full the domestic hot water requirements throughout the day.
The storage temperature set point and timing are eld settings.
[1-00] Status: denes whether the domestic water heating
(storage mode) during night is enabled (1) or not (0).
[1-01] Start time: time of the night at which the domestic water
should be heated.
[1-02] Status: denes whether the domestic water heating
(storage mode) during daytime is enabled (1) or not (0).
[1-03] Start time: time of the day at which the domestic water
should be heated.
Refer to "[b] Domestic hot water set points" on page 40 for
temperature set points.
Method 2 Space heating based on ON/OFF instruction
During operation When the schedule timer switches space heating OFF,
the controller will be switched off (operation LED will stop
working). Note that this has no inuence on the domestic
water heating.
When pushing
the button
The schedule timer for space heating will stop (when
active at that moment) and will start again at the next
scheduled ON function.
The "last" programmed command overrules the
"preceding" programmed command and will remain
active until the "next" programmed command occurs.
Example: imagine the actual time is 17:30 and actions
are programmed at 13:00, 16:00 and 19:00. The "last"
programmed command (16:00) overruled the "previous"
programmed command (13:00) and will remain active
until the "next" programmed command (19:00) occurs.
So in order to know the actual setting, one should consult
the last programmed command. It is clear that the "last"
programmed command may date from the day before.
Refer to the operation manual.
The controller will be switched off (operation LED will
stop working).
However the schedule timer icon will stay displayed
which means that the domestic heating stays enabled.
When pushing
the / button
The schedule timer for space heating and domestic
water heating along with the quiet mode will be stopped
and will not start again.
The schedule timer icon will not be displayed anymore.
1 Schedule timer
2 Setback function
3 When both setback function and schedule timer are enabled
A Setback function
B ON/OFF instruction
t Time
T Temperature set point
Room temperature
Leaving water temperature
t
18
18
°C
60
60
°C60°C
18°C
A
5:00
5:00
23:00
23:00
5:0023:00
2
B
t
9:00
16:00
19
19
°C 19
19
°C
22
22
°C
21
21
°C
62
62
°C 62
62
°C
65
65
°C
64
64
°C
19°C19°C
22°C
21°C
62°C62°C
65°C
64°C
1
OFF ONON
6:300:30
B
t
6:30 9:00
16:00
23:00
19
19
°C 19
19
°C
22
22
°C
21
21
°C
62
62
°C 62
62
°C
65
65
°C
64
64
°C
19°C19°C
22°C
21°C
62°C62°C
65°C
64°C
3
OFF ONON
18
18
°C
60
60
°C60°C
18°C
NOTE
Make sure the domestic hot water is only heated up
to the domestic hot water temperature you require.
Start with a low domestic hot water storage
temperature set point, and only increase if you
feel that the domestic hot water supply
temperature is not sufcient for your needs (this
depends on your water using pattern).
Make sure the domestic hot water is not heated
unnecessary. Start with activating automatic
storage during night (default setting). If it seems
that the domestic hot water night storage
operation is not sufcient for your needs, an
additional storage during daytime can be set.
For energy-saving purposes, it is advised to
enable the weather dependent domestic water
heating. Refer to setting "[b-02]" on page 40.