Daikin RMXS140E8V1B [238/393] A up and down direction

Daikin RMXS140E8V1B [238/393] A up and down direction
SiBE18-821 Instruction
Operation Manual 225
The setting is impossible for fan operation.
NOTE
The setting temperature range of the remote con-
troller is 16˚C to 32˚C.
FAN SPEED CONTROL
Press FAN SPEED CONTROL button.
High or Low fan speed can be selected.
The micro computer may sometimes control the fan
speed in order to protect the unit.
AIR FLOW DIRECTION ADJUST
There are 2 ways of adjusting the air discharge
angle.
1. A. Up and down adjustment
2. B. Left and right direction
Fig. 1
A. UP AND DOWN DIRECTION
The movable limit of the flap is changeable. Con-
tact your Daikin dealer for details.
Press the AIR FLOW DIRECTION ADJUST
button to select the air direction as following.
The AIR FLOW FLAP display
swings as shown the left and
the air flow direction continu-
ously varies. (Automatic swing
setting)
Press AIR FLOW DIRECTION
ADJUST button to select the air
direction of your choice.
The AIR FLOW FLAP display
stops swinging and the air flow
direction is fixed (Fixed air flow
direction setting).
A. Up and down
direction
B. Left and right direction
swing
MOVEMENT OF THE AIR FLOW FLAP
For the following conditions, micro computer con-
trols the air flow direction so it may be different from
the display.
Operation mode includes automatic operation.
B. LEFT AND RIGHT DIRECTION
Adjusting air flow direction in the left and right
direction. (Refer to Fig. 1)
NOTE
Only make adjustments after you have stopped
the air flow direction swing in a position where
adjustments are possible. Your hand may get
caught if you attempt to make adjustments while
the unit is swinging.
Operate in the following order.
The timer is operated in the following two ways.
.... The system stops
operating after the set time has elapsed.
Programming the start time ( )
.... The system starts
operating after the set time has elapsed.
The timer can be programmed a maximum of 72
hours.
The start and the stop time can be simultaneously
programmed.
TIMER MODE START/STOP
Press the TIMER MODE START/STOP button
several times and select the mode on the
display.
The display flashes.
For setting the timer stop .... “
For setting the timer start .... “
Operation
mode
Cooling Heating
Operation
condition
When room
temperature is
lower than the
set temperature
When room
temperature is
higher than the
set temperature
At defrost opera-
tion
When operating continuously at
downward air flow direction
PROGRAM TIMER OPERATION
1
Programming the stop time ( )