Fluke 1650B [46/62] General specifications

Fluke 1650B [46/62] General specifications
165XB
Users Manual
38
General Specifications
Specification Characteristic
Size 10 cm (L) x 25 cm (W) x 12.5 cm (H)
Weight (with batteries) 1.5 kg
Battery size, quantity Type AA, 6 ea.
Battery type Alkaline supplied.
Usable with 1.2 V NiCd or NiMH batteries (not
supplied)
Battery life (typical) 200 hours idling
Fuse T3.15 A, 500 V, 1.5 kA 6.3 x 32 mm (PN 2030852)
Operating Temperature -10 °C to 40 °C
Storage Temperature -10 °C to 60 °C indefinitely (to -40 °C for 100 hrs)
Relative Humidity Noncondensing <10 °C
95 % 10 to 30 °C; 75 % 30 to 40 °C
Operating Altitude 0 to 2000 meters
Shock, Vibration Vibration to Class 3 per Mil-Prf-28800F
1 meter drop test, six sides, oak floor
Sealing IP-40
EMC Complies with EN61326-1: 2006
Safety Complies with EN61010-1 Ed 2.0 (2001-02),
UL61010, ANSI/ISA -s82.02.01 2000 and
CAN/CSA c22.2 No.1010 2nd edition
Overvoltage Category III (CAT III), 600 V
Measurement Category III is for measurements
performed in the building installation. Examples
are distribution panels, circuit breakers, wiring and
cabling.
Performance EN61557-1, EN61557-2,
EN61557-3, EN61557-4, EN61557-5, EN61557-6,
EN61557-7 Second edition. EN61557-10 First
edition.
Maximum voltage between
any terminal and earth
ground
500 V
Surge Protection 6 kV peak per EN 61010-1 Ed. 2.0 (2001-02)