Bosch PFS 105 E (0603206200) [18/193] Maintenance and service

Bosch PFS 105 E (0603206200) [18/193] Maintenance and service
18 | English
1 609 929 Y14 | (23.8.11) Bosch Power Tools
Adjusting the Spray Pattern (see figure F)
f Never actuate the trigger switch 9 while adjusting the
air cap 2.
Loosen the union nut 3.
Turn the air cap 2 to the requested position.
Firmly retighten the union nut.
Adjusting the Spraying Capacity (see figure G)
To adjust the requested spraying capacity, turn the thumb-
wheel 5:
I: Min. spraying capacity,
IIII: Max. spraying capacity.
Adjusting the Air Flow (see figure H)
Turn control knob 16 to adjust the air flow and the pres-
sure for the spray material being used.
It is recommended to start with the maximum air flow.
Transport
The filled spray gun or a closed container with spray material
can be placed in the set-down port 17 for transport. The hold-
ing fixture retains the spray gun firmly in the set-down port.
Spray material cannot run out.
Place down the spray gun on the set-down port and push in
against the resistance until tightly seated.
Maintenance and Service
Maintenance and Cleaning
f Before any work on the machine itself, pull the mains
plug.
Cleaning (see figures IK)
Proper cleaning is the requirement for flawless operation of
the spray gun. Improper or lack of cleaning voids warranty
claims.
Always clean the spray gun and the container with the respec-
tive diluting agent (paint thinner or water) for the spray mate-
rial being used.
Never immerse the complete spray gun into the cleaning
agent.
Never clean the nozzle and air holes of the spray gun with
pointed metal objects.
Do not pour diluted spray material back into the original spray
material drum/tin for storage.
Clean the spray gun thoroughly after having sprayed material
hazardous to one's health.
Switch the base unit off and pull the trigger switch 9 of the
spray gun so that the spray material can flow back into the
container.
Unscrew the container 8 and empty the remaining spray
material.
Fill diluting agent (paint thinner or water) into the contain-
er and screw it to the spray gun.
Shake the spray gun several times.
Switch the base unit on and spray the diluting agent into an
empty material tin.
Repeat the last three steps until clear diluting agent emerg-
es from the spray gun.
Switch the base unit off again.
Completely empty the container 8.
Check if the suction tube with the container seal 10 is free
of spray material and undamaged.
Clean the outside of the container and the spray gun with a
cloth moistened in paint thinner.
Unscrew the union nut 3 and the air cap 2.
Air cap Jet Application
A
Vertical flat jet for horizontal
working direction
B
Horizontal flat jet for vertical
working direction
C
Round jet for corners, edges and
hard to reach locations
Spraying capacity Adjustment
Too much material on target
area:
The spraying capacity must
be reduced.
Turn the thumbwheel 5 in
direction I.
Not enough material on target
area:
The spraying capacity must
be increased.
Turn the thumbwheel 5 in
direction IIII.
Minimal
air flow
Maximum
air flow
Air Flow Adjustment
Too much fog of coating
material:
The air flow must be
reduced.
Turn control knob 16
toward the left.
Atomisation too coarse: The air flow must be
increased.
Turn control knob 16
toward the right.
Air Flow Adjustment
OBJ_BUCH-420-002.book Page 18 Tuesday, August 23, 2011 12:08 PM

Содержание

Похожие устройства

OBJ BUCH 420 002 book Page 18 Tuesday August 23 2011 12 08 PM 181 English Adjustingthe Spray Pattern see figure F Never actuate the trigger switch 9 whileadjusting the air cap 2 Air Flow Adjustment Atomisation too coarse The airflow mustbe increased Loosen the union nut 3 Turn the air cap 2 to the requested position Turn control knob 16 toward the right Firmly retighten the union nut Air cap Jet Application A Transport Vertical flat jetfor horizontal working direction The filled spray gun or a dosed container with spray material B Spray material cannot run out Horizontal flat jet for vertical working direction Placedown the spray gun on theset down port and push in C Maintenance and Service can be placed in the set down port 17 for transport The hold ing fixture retains the spray gun firmly in the set down port against the resistance until tightly seated Roundjetfor corners edges and hard to reach locations Maintenance and Cleaning Before any work on the machine itself pull the mains Adjustingthe Spraying Capacity see figureG To adjust the requested spraying capacity turn the thumb wheel 5 PlugCleaning see figures I K Proper cleaning is the requirement for flawless operation of I Min spraying capacity the spray gun Improper or lack of cleaning voids warranty claims Illi Max spraying capadty Sprayingcapacity Adjustment Always clean the spray gun and the container with the respec Too much material on target Thespraying capacity must tive diluting agent paint thinner or water for the spray mate area rial being used be reduced Never immerse the complete spray gun into the cleaning agent Never clean the nozzle and air holes of the spray gun with pointed metal objects Do not pour diluted spray material back into the original spray Not enough material on target The spraying capacity must area be increased material drum tin for storage Clean the spray gun thoroughly after having sprayed material hazardous to one s health Switch the base unit off and pull the trigger switch 9 of the spray gun so that the spray material can flow back into the container Adjusting the Air Flow see figure H Unscrew the container 8 and empty the remaining spray material Turn control knob 16 to adjust the air flow and the pres Fill diluting agent paint thinner or water into the contain sure for the spray material being used Minimal rrrrnTh Maximum airflow er and screw it to the spray gun airflow It is recommended tostartwi th the maximum air flow Air Flow Adjustment Too much fog of coating The air flow must be material reduced Turn control knob 16 toward the I eft Shakethespraygun several times Switch the base unit on and spray the di lu ti ng agent intoan empty material tin Repeat the I ast three steps until clear di luti ng agent emerg es from the spray gun Switch the base unit off again Completely empty the container 8 Check if the suction tube with the container seal 10 is free of spray material and undamaged Clean the outsideof the container and the spray gun with a cloth moistened in paint thinner Unscrew the union nut 3 and the air cap 2 1609 929 Y141 23 8 11 Bosch Power Tools f A