Daikin FXSQ50P7VEB [356/370] Fxaq15pa 20pa 25pa 32pa 40pa 50pa 63pav1

Daikin FXZQ20MVES [356/370] Fxaq15pa 20pa 25pa 32pa 40pa 50pa 63pav1
Wiring Diagrams for Reference SiBE311209
347 Appendix
FXAQ15PA / 20PA / 25PA / 32PA / 40PA / 50PA / 63PAV1
INDOOR UNIT
A2P
A3P
A1P
SS1
H1P
X2A
BS1
H2P
X2M
SS2
H3P
H4P
X1A
X1A
X24A
RED
L
NOTE
)
8
L
N
N
T2
PNK
T1
WHT
X2M
A1P
F2
YLW
F1
ORG
X2M
P2
BLU
P1
BLK
SS1
X1M
A1P
HAP
P2
X1M
R1T
P1
HAP
BLU
RED
BRN
ORG
WHT
X1M
WHT
SIDE
FRONT
M
MSW
Y1E
M1S
M1F
CONNECTOR FOR OPTIONAL PARTS
WIRED REMOTE CONTROLLER
POWER SUPPLY
1~ 220-240V 50Hz
CONTROL BOX
(
INDOOR UNIT
)
MS
3~
RECEIVER/DISPLAY UNIT
(
WIRELESS REMOTE CONTROLLER
)
WIRED REMOTE
CONTROLLER
INPUT FROM OUTSIDE
TRANSMISSION WIRING
CENTRAL REMOTE CONTROLLER
NOTE
)
2
NOTE
)
5
A1P
F1U
HAP
M1F
M1S
R1T
R2T
R3T
X1M
X2M
Y1E
PC
A2P
A3P
BS1
H1P
H2P
H3P
H4P
SS1
SS2
PRINTED CIRCUIT BOARD
FUSE
(
T
,
3.15AH
,
250V
)
LIGHT EMITTING DIODE
(
SERVICE MONITOR GREEN
)
MOTOR
(
INDOOR FAN
)
MOTOR
(
SWING FLAP
)
THERMISTOR
(
AIR
)
THERMISTOR
(
COIL LIQUID PIPE
)
THERMISTOR
(
COIL GAS PIPE
)
TERMINAL BLOCK
(
CONTROL
)
TERMINAL BLOCK
(
POWER
)
ELECTRONIC EXPANSION VALVE
POWER CIRCUIT
PRINTED CIRCUIT BOARD
PRINTED CIRCUIT BOARD
PUSH BUTTON
(
ON/OFF
)
LIGHT EMITTING DIODE
(
ON-RED
)
LIGHT EMITTING DIODE
(
TIMER-GREEN
)
LIGHT EMITTING DIODE
(
FILTER SIGN-RED
)
LIGHT EMITTING DIODE
(
DEFROST-ORANGE
)
SELECTOR SWITCH
(
MAIN/SUB
)
SELECTOR SWITCH
(
WIRELESS ADDRESS SET
)
RECEIVER/DISPLAY UNIT
(
ATTACHED
TO WIRELESS REMOTE CONTROLLER
)
NOTES
)
2.
IN CASE USING CENTRAL REMOTE CONTROLLER
,
CONNECT IT
TO THE UNIT IN ACCORDANCE WITH THE ATTACHED INSTALLATION MANUAL.
3. SYMBOLS SHOW AS FOLLOWS : RED : RED WHT : WHITE GRN : GREEN
PNK : PINK YLW : YELLOW BLK : BLACK ORG : ORANGE BLU : BLUE BRN : BROWN
R1T
SS1
THERMISTOR
(
AIR
)
SELECTOR SWITCH
(
MAIN/SUB
)
X15A
X24A
X35A
X38A
CONNECTOR
(
FLOAT SWITCH
)
CONNECTOR
(
WIRELESS REMOTE CONTROLLER)
CONNECTOR
(
GROUP CONTROL ADAPTOR)
CONNECTOR (ADAPTOR FOR MULTI TENANT)
4. SHOWS SHORT CIRCUIT CONNECTOR.
5. WHEN CONNECTING THE INPUT WIRES FROM OUTSIDE
,
FORCED OFF OR ON/OFF CONTROL OPERATION CAN BE
SELECTED BY REMOTE CONTROLLER. IN DETAILS
,
REFER
TO THE INSTALLATION MANUAL ATTACHED TO THE UNIT.
6. REMOTE CONTROLLER MODEL VARIES
ACCORDING TO THE COMBINATION
SYSTEM
,
CONFIRM ENGINEERING DATA
AND CATALOGS
,
ETC. BEFORE CONNECTING.
7. CONFIRM THE METHOD OF SETTING THE SELECTOR
SWITCH
(
SS1
,
SS2
)
OF WIRED REMOTE CONTROLLER
AND WIRELESS REMOTE CONTROLLER BY INSTALLATION
MANUAL AND ENGINEERING DATA
,
ETC.
8. X15A
,
X24A
,
X35A AND X38A ARE CONNECTED WHEN THE
OPTIONAL ACCESSORIES ARE USED.
3D076497
R1T
R3T R2T
A1P
GRN/YLW
GRN
F1U
WHT
X27A
PC
X20A
X36A
X7A
X15A
NOTE
)
8
X38AX35A
X30A
NOTE
)
8NOTE
)
8
HAP
X18A
X19A
X14A
X24A
NOTE
)
8
1. : TERMINAL : CONNECTOR : PROTECTIVE EARTH
(
SCREW
)
:
FIELD WIRING : CONNECTOR : NOISELESS EARTH

Содержание

Скачать