Icom IC-M802 [27/78] Ic m802_usa qxd 02 0 11 39 page 19

Icom IC-M802 [27/78] Ic m802_usa qxd 02 0 11 39 page 19
2001 NEW
19
7
CALL PROCEDURE
7
DD
Regular distress call
Transmit a distress call after selecting Distress
in the DSC menu.
NEVER USE THE DISTRESS CALL WHEN YOUR
SHIP IS NOT IN AN EMERGENCY. DISTRESS
CALLS CAN BE USED ONLY WHEN IMMEDIATE
HELP IS NEEDED.
q Push [DSC] to select DSC watch mode.
w Push [MODE set] to select the DSC menu.
e Rotate [CH] to select Distress, then push
[ENT].
r Rotate [CH] to select the desired nature then push
[ENT].
t Verify the position and UTC time data, then push
[ENT].
When no position and time data is applied to [GPS],
your position and UTC time should be input in this step.
y Rotate [CH] to select the desired distress fre-
quency, then push [ENT].
After pushing [ENT], return to the DSC menu as shown
in step q.
u Lift up the distress switch cover, push [DISTRESS]
for 5 sec. to transmit the distress call.
The distress call is transmitted on the emergency fre-
quency selected in step y.
i After transmitting the call, the transceiver is set to
the phone emergency frequency automatically.
The DSC receiver circuit is still working to receive an
acknowledgement call on the previous frequency.
The distress call transmission and acknowledgement
reception are performed on the all distress frequencies
(2187.5, 4207.5, 6312.0, 8414.5, 12577.0 and
16804.5 kHz) in sequence when Single;six
frequency is selected in step y.
o When receiving an acknowledgement, push [CAN-
CEL/CALL] to stop the alarm then reply to the con-
nected station via the transceivers microphone.
The acknowledgement is memorized into the RX mem-
ory channel. (p. 38)
RX
J3E
<
Wait
for
ACK
>
Lat
34
34'N
Lon135
34'E
12:34
SP
GPS
Exit
*******
Distress
*******
--------
Attempt
-------
Single;six
frequency
Single;
2187.5kHz
Single;
4207.5kHz
Single;
6312.0kHz
Single;
8414.5kHz
Single;12577.0kHz
Single;16804.5kHz
OKSEL
Ç
*******
Distress
*******
---
Position
&
time
----
Latitude
Longitude
UTC
34
34'N
135
34'E
12:34
OKNull
*******
Distress
*******
--------
Nature
--------
Undesignated
Fire,Explosion
Flooding
Collision
Grounding
Capsizing
Sinking
Disable
adrift
Abandoning
ship
Piracy
attack
Man
overboard
EPIRB
emission
Ç
OKSEL
*******
DSC
MENU
*******
--------
Select
--------
Position
Individual
Group
All
ships
Position
REQ
Distress
Test
RX
memory
TX
memory
Set
up
Exit
Ç
OKSEL
[MODE SET][ENT][DSC]
[FREQ/CH][CH] [F][CANCEL/CALL]
IC-M802_USA.qxd 02.5.30 11:39 Page 19