33
9 Technical Specifications
OUTPUTS:
4 IR on 3.5mm mini jacks
PORTS:
2 RS-232 serial on 3-pin terminal blocks
1 Ethernet on an RJ-45 connector
1 IR sensor (IR learning)
1 USB on a mini USB connector for programming
SUPPORTED SERIAL PORT
BAUD RATES:
1200, 2400, 4800, 9600, 19200, 38400, 57600, 15200bps
RS-232 COMMUNICATION:
Transparent up to 115200bps
IR EMITTER CABLE RANGE:
80m (260ft)
SUPPORTED IR INPUT
FREQUENCIES:
20kHz to 60kHz
SUPPORTED IR OUTPUT
FREQUENCIES:
20kHz to 1.2MHz
MAXIMUM DATA HANDLING OF
DEVICE:
Up to 150kbps (summed on all ports, see Section 9.1)
SUPPORTED WEB
BROWSERS:
Windows 7 and higher:
Internet Explorer (32/64 bit) version 11
Firefox version 30
Chrome version 35
MAC:
Chrome version 35
Firefox version 27
Safari version 7
Android OS:
Chrome version 35
iOS:
Chrome version 35
Safari version 7
POWER CONSUMPTION:
5V DC, 230mA
OPERATING TEMPERATURE:
0° to +40°C (32° to 104°F)
STORAGE TEMPERATURE:
–40° to +70°C (–40° to 158°F)
HUMIDITY:
10% to 90%, RHL non-condensing
COOLING:
Convection
ENCLOSURE TYPE:
Aluminium
RACK MOUNT:
With optional rack adapter
DIMENSIONS:
12cm x 7.5cm x 2.44cm
(4.72” x 2.95” x 0.96”) W, D, H
PRODUCT WEIGHT:
0.182kg (0.4lbs) approx.
SHIPPING WEIGHT:
0.43kg (0.95lbs) approx.
VIBRATION:
ISTA 1A in carton (International Safe Transit Association)
SAFETY REGULATORY
COMPLIANCE:
CE
ENVIRONMENTAL
REGULATORY COMPLIANCE:
Complies with appropriate requirements of RoHs and WEEE
INCLUDED ACCESSORIES:
Power adapter, IR Cable C-A35M/IRE-10
Содержание
- User manual 1
- Contents 4
- Figures 4
- Introduction 6
- Achieving the best performance 7
- Getting started 7
- Safety instructions 7
- Recycling kramer products 8
- Overview 9
- About the power over ethernet feature 11
- Defining the fc 26 ethernet controller 12
- Figure 2 defines the front panel of the fc 26 12
- Figure 3 defines the rear panel of the fc 26 13
- Configuring the fc 26 ethernet controller 14
- Initial configuration and use overview 14
- Configuring a virtual port on the pc 16
- Setting up an ethernet connection on the pc 16
- Connecting the fc 26 17
- Connecting the ethernet port directly to a pc 18
- Connecting via ethernet 18
- Connecting the ethernet port via a network hub or switch 21
- Connecting to the fc 26 via rs 232 or ir 22
- Browsing the web pages 23
- Remote operation via the web pages 23
- Loading and saving configurations 24
- Connected clients page 25
- Device settings page 26
- Communication page 28
- Serial port settings page 29
- Ir command learner page 30
- Not available for normal operation 30
- Note while learning is in progress the four ir out leds light and the fc 26 is 30
- The ir command learner page allows you to teach the fc 26 ir commands 30
- These can be saved for later use 30
- On the security page click on 31
- Security page 31
- The confirmation popup is displayed as shown in figure 18 31
- The security page allows you to turn logon authentication on or off 31
- To activate web page security 31
- Valid user and password for default logon credentials see section 10 31
- When security is on access to the web pages is granted only on submission of a 31
- Logs page 33
- About us page 34
- Configuring and maintaining the fc 26 36
- Ir learning 36
- Resetting to the factory default settings 37
- Upgrading the firmware 37
- Technical specifications 38
- Data handling performance 39
- Example bandwidth calculation 39
- Default communication parameters 40
- Default logon authentication 40
- Ip address after performing a factory reset the dhcp and the ip address are set 40
- Note the fc 26 is dispatched from the factory with dhcp enabled and a random 40
- To the values shown below 40
- Command string 41
- Device long response 41
- Device message format 41
- Host message format 41
- Kramer protocol 3000 41
- Kramer protocol 3000 syntax 41
- Simple command 41
- Command terms 42
- Chaining commands 43
- Command forms 43
- Entering commands 43
- Maximum string length 43
- Kramer protocol 3000 command list 44
- Kramer protocol 3000 detailed commands 45
- This section lists the detailed commands applicable to the fc 26 45
- Ir status 66
- Ir transmit status 66
- Parameters 66
- Parity types 66
- Serial types 66
Похожие устройства
- Kramer FC-50 Руководства по эксплуатации
- Kramer VP-14 Руководства по эксплуатации
- Kramer VP-14xl Руководства по эксплуатации
- Kramer PL-50 Руководства по эксплуатации
- Kramer RB-6 Руководства по эксплуатации
- Kramer PL-15 Руководства по эксплуатации
- Kramer PT-4iREX Руководства по эксплуатации
- Kramer PT-5R/T Руководства по эксплуатации
- Kramer 401DN Руководства по эксплуатации
- Kramer 401C Руководства по эксплуатации
- Kramer VP-100 Руководства по эксплуатации
- Kramer 7408 Руководства по эксплуатации
- Ritmix RAT-310 Инструкция по эксплуатации
- Ritmix RAT-501 Инструкция по эксплуатации
- Ritmix RAT-201 Инструкция по эксплуатации
- Kramer 7508 Руководства по эксплуатации
- Kramer FC-7501 Руководства по эксплуатации
- Kramer FC-331 Руководства по эксплуатации
- Kramer FC-332 Руководства по эксплуатации
- Kramer FC-113 Руководства по эксплуатации