Zyxel MGS-3712F [248/284] The following table describes the labels in this screen

Zyxel MGS-3712F [248/284] The following table describes the labels in this screen
Chapter 73 Additional Commands
Ethernet Switch CLI Reference Guide
248
The following table describes the labels in this screen.
This example displays multicast VLAN configuration on the
Switch.
Table 157 show hardware-monitor
LABEL DESCRIPTION
Temperature Unit This field displays the unit of measure for temperatures in this screen.
Temperature This field displays the location of the temperature sensors.
Current This field displays the current temperature at this sensor.
Max This field displays the maximum temperature measured at this sensor.
Min This field displays the minimum temperature measured at this sensor.
Threshold This field displays the upper temperature limit at this sensor.
Status Normal: The current temperature is below the threshold.
Error: The current temperature is above the threshold.
FAN Speed(RPM) This field displays the fans in the Switch. Each fan has a sensor that is
capable of detecting and reporting when the fan speed falls below the
threshold.
Current This field displays the current speed of the fan at this sensor.
Max This field displays the maximum speed of the fan measured at this sensor.
Min This field displays the minimum speed of the fan measured at this sensor. It
displays "<41" for speeds too small to measure. (See the User’s Guide to
find out what speeds are too small to measure in your Switch.)
Threshold This field displays the minimum speed at which the fan should work.
Status Normal: This fan is running above the minimum speed.
Error: This fan is running below the minimum speed.
Voltage(V) This field displays the various power supplies in the Switch. Each power
supply has a sensor that is capable of detecting and reporting when the
voltage is outside tolerance.
Current This field displays the current voltage at this power supply.
Max This field displays the maximum voltage measured at this power supply.
Min This field displays the minimum voltage measured at this power supply.
Threshold This field displays the percentage tolerance within which the Switch still
works.
Status Normal: The current voltage is within tolerance.
Error: The current voltage is outside tolerance.
sysname> show multicast vlan
Multicast Vlan Status
Index VID Type
----- ---- ----------
1 123 MVR