Daikin RXYQ34PY1 [314/398] Master unit central connector setting table

Daikin RXYQ34PY1 [314/398] Master unit central connector setting table
Si34-601A Troubleshooting (OP: Central Remote Controller)
Troubleshooting 303
Master-Slave Unit
Setting Table
Combination of Intelligent Touch Controller and Central Remote Controller
CRC: Central remote controller <DCS302C1>
Intelligent Touch controller: < >
The patterns marked with “
” have nothing to do with those described in the list of Setting of master unit central setting connector.
Master Unit
Central
Connector
Setting Table
The master unit central setting connector (CN1/X1A) is mounted at the factory.
To independently use a single unit of the intelligent Touch controller or a single unit of the
central remote controller, do not dismount the master unit central setting connector (i.e., use
the connector with the factory setting unchanged).
To independently use the schedule timer, insert an independent-use setting connector.
No independent-use setting connector has been mounted at the factory. Insert the
connector, which is attached to the casing of the main unit, in the PC board (CN1/X1A).
(Independent-use connector=Master unit central setting connector)
To use two or more central equipment in combination, make settings according to the table
shown below.
(*1) The intelligent Touch controller and the schedule timer are not available for combined use.
(*2) The intelligent Touch controller, central remote controller, and the unified ON/OFF controller have been set to "Provided with the master
unit central setting connector" at the factory. The schedule timer has been set to "Not provided with the master unit central setting
connector" at the factory, which is attached to the casing of the main unit.
#1 #2 #3 #4
Pattern
1-00~4-15
Master/
Slave
5-00~8-15
Master/
Slave
1-00~4-15
Master/
Slave
5-00~8-15
Master/
Slave
CRC Master CRC Master CRC Slave CRC Slave
CRC Master CRC Slave
Intelligent
Touch
controller
Master
Intelligent
Touch
controller
Slave
CRC Master
Intelligent
Touch
controller
Slave
Intelligent
Touch
controller
Master CRC Slave
CRCMaster——————
Intelligent
Touch
controller
Master——————
#1 #2 #3 #4
Master
Slave
DCS601C51
Pattern
Central equipment connection pattern Setting of master unit central setting connector(*2)
Intelligent
Touch
controller
Intelligent
Touch
controller
Central
remote
controller
Unified
ON/OFF
controller
Schedule
timer
Central
remote
controller
Unified
ON/OFF
controller
Schedule
timer
1 to 2
units
× (*1)
Only a
single unit:
"Provided",
Others: "Not
provided"
Only a
single unit:
"Provided",
Others: "Not
provided"
Only a
single unit:
"Provided",
Others: "Not
provided"
Only a
single unit:
"Provided",
Others: "Not
provided"
1 unit
1 unit
× (*1)
Provided Not provided
1 to 2
units
1 to 8
units
× (*1)
All "Not
provided"
All "Not
provided"
× (*1)
1 to 4
units
1 to 16
units
1 unit Not provided
1 unit Not provided
1 to 16
units
 1 unit Not provided
 1 unit Provided