Graco ProDispense [33/74] Alarm history screen

Graco ProDispense [33/74] Alarm history screen
Dispense Mode
309301K 33
Press the left or right arrow key to select Alarms. This screen summarizes the last five alarms that have
occurred.
Out of Tolerance Alarm
This alarm occurs when the current actual dispense is either less than target – tolerance or greater than target + tol-
erance.
Dispense Timeout Alarm
The controller stops an active dispense and initiates this alarm when the current dispense is not finished by the end
of the Timeout. Timeout is a value entered during Fluid Setup (page 27).
Invalid K-factor Alarm
This alarm occurs if the meter K-factor is set to zero (00.000).
Memory Failure Alarm
This alarm occurs when the memory has been replaced but not programmed or when the memory has become cor-
rupt.
Alarm History Screen
Alarms
Press Print key to print an Alarms Report.
ALARMS
Date Time Description Recipe Fluid
03/09 9:39 Invalid K-factor 10 1
03/08 14:32 Out of Tolerance 0 1
03/05 15:01 Timeout 6 2
03/05 8:12 Out of Tolerance 62
03/02 10:59 Invalid K-factor 0 3
Run Totals
Alarms
Print
NOTE: See page 36 for alarm troubleshooting information.