Lowara NSCF 300-450/3150/W45 VDC4 [118/204] E nsc series operating characteristics at 50 hz 4 poles

Lowara NSCF 100-160/370/W25 VCC4 [118/204] E nsc series operating characteristics at 50 hz 4 poles
118
e-NSC SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density ρ = 1,0 Kg/dm
3
and kinematic viscosity ν = 1 mm
2
/sec.
0 200 400 600 800 1000 1200 1400
P
P
[kW]
50
100
150
200
250
300
0 25 50 75 100 125 150 175 200 225 250 275 300 325 350 375
P
P
[HP]
50
100
150
200
250
300
350
400
NPSH [m]
0
4
8
12
NPSH [ft]
10
15
20
25
30
35
Q
[m³/h]
Q
[l/s]
H
[m]
30
40
50
60
70
80
90
100
110
0 1000 2000 3000 4000 5000 6000
H [ft]
100
125
150
175
200
225
250
275
300
325
350
0 1000 2000 3000 4000 5000
Q
[US gpm]
Q
[Imp gpm]
83.3
75
70
60
50
η
ηη
η
[%]
80
82
81.2
80
82
82.6
80.5
75
70
83
200-500/3150
200-500/1320
200-500/1600
200-500/2000
200-500/2500
200-500/3150
200-500/1320
200-500/1320
200-500/1600
200-500/2000
200-500/2500
200-500/3150
~ 1475 [rpm]
ISO 9906:2012 - Grade 3B
NSC 200-500
NSC200-500_4P50_B_CH

Содержание