Lowara NSCF 300-450/3150/W45 VDC4 [78/204] E nsc series operating characteristics at 50 hz 4 poles

Lowara NSCF 125-315/2000/W25 VCC [78/204] E nsc series operating characteristics at 50 hz 4 poles
78
e-NSC SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES
NSC 32-160 ~ 1450 [rpm] ISO 9906:2012 - Grade 3B
0 10 20 30 40 50 60 70 80
0123456
Q [Imp gpm]
Q [l/s]
32-160/05
32-160/05A
32-160/03
32-160/02
63.4
63.3
62.1
58.5
62
62
60
60
58
58
56
56
54
54
52
52
0 10 20 30 40 50 60 70 80 90 100
0
5
10
15
20
25
30
0
1
2
3
4
5
6
7
8
9
10
Q [US gpm]
H [ft]
H[m]
η[%]
η[%]η[%]
η[%]
32-160/05
0
2
4
6
8
0
1
2
3
NPSH[ft]
NPSH[m]
32-160/05
32-160/05A
32-160/03
32-160/02
0.0
0.2
0.4
0.6
0.8
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0 5 10 15 20
Pp[HP]
Pp[kW]
Q [m
3
/h]
NSC32
-
160_4P50_C_CH
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density ρ = 1,0 Kg/dm
3
and kinematic viscosity ν = 1 mm
2
/sec.