REPORTS AND DECLARATIONS
i) Test reports
a) Factory Test Report
(not available for all pump types; contact Customer Service in advance)
- Test report compiled at the end of the assembly line, including flow-head performance test
(ISO 9906:2012 – Grade 3B) and tightness test.
b) Audit Test Report
- Test report for electric pumps compiled in the test room, comprising flow-head-pump input-pump efficiency
performance test (ISO 9906:2012 – Grade 3B)
c) NPSH Test Report
- Test report for electric pumps compiled in the test room, comprising flow-NPSH performance test
(ISO 9906:2012 – Grade 3B)
d) Noise Test Report
- Report indicating sound pressure and power measurements (EN ISO 20361, EN ISO 11203, EN ISO 4871)
e) Vibration Test Report
(unavailable for submerged or submergible pumps)
- Report indicating vibration measurements (ISO 10816-1)
ii) Declaration of product conformity with the technical requirements indicated in the order
a) EN 10204:2004 - type 2.1
- does not include test results on supplied or similar products.
b) EN 10204:2004 - type 2.2
- includes test results (materials certificates) on similar products.
iii) Issue of a further EC Declaration of Conformity,
- in addition to the one accompanying the product, it comprises references to European law and the main
technical standards (e.g.: MD 2006/42/EC, EMCD 2004/108/EC, ErP 2009/125/EC).
N.B.: if the request is made after receipt of the product, communicate the code (name) and serial number (date
+ progressive number).
iv) Manufacturer’s declaration of conformity
- relative to one of more types of products without indicating specific codes and serial numbers.
v) Other certificates and/or documentation on request
- subject to availability or feasibility.
vi) Duplication of certificates and/or documentation on request
- subject to availability or feasibility.