Lowara NSCF 300-450/3150/W45 VDC4 [85/204] E nsc series operating characteristics at 50 hz 4 poles

Lowara NSCF 150-315/550/W45 VCC4 [85/204] E nsc series operating characteristics at 50 hz 4 poles
85
e-NSC SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES
NSC 40-250 ~ 1450 [rpm] ISO 9906:2012 - Grade 3B
0 20 40 60 80 100 120
0123456789
Q [Imp
gpm]
Q [l/s]
40-250/30
40-250/22
40-250/22A
40-250/15
63.9
60.4
59.1
58.8
57.9
63
63
61
61
59
59
57
55
53
40-250/**
0 20 40 60 80 100 120 140
0
10
20
30
40
50
60
70
80
90
0
5
10
15
20
25
30
Q [US gpm]
H [ft]
H[m]
η[%]
η[%]η[%]
η[%]
40-250/30
0
2
4
6
0
1
2
NPSH[ft]
NPSH[m]
40-250/30
40-250/22
40-250/22A
40-250/**
40-250/15
0
1
2
3
4
0
1
2
3
0 5 10 15 20 25 30 35
Pp[HP]
Pp[kW]
Q [m
3
/h]
NSC40
-
250_4P50_D_CH
**= 1.1 kW (/11)
NSCS, NSCF, NSCC
**= 1.5 kW (/15A) NSCE
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density ρ = 1,0 Kg/dm
3
and kinematic viscosity ν = 1 mm
2
/sec.

Содержание