AXIOMET AX-EL300W60A Расширенная инструкция онлайн [26/72] 527990

AXIOMET AX-EL300W60A Расширенная инструкция онлайн [26/72] 527990
In local control, if the input is turned on, the load status can not be switched directly among the basic
modes, transient operation, list operation and battery discharge operation etc.. The load can be switched
from one operation status to another operation status only when the input is turned off.
In remote control mode, it is better to send the command INPUT ON/OFF in the end to turn on
the load.
3.9.2. Von Point / Voff Point / Von Latch
When the rising speed or falling speed of tested power supply is slow, the load maybe protect the tested
power supply. The load provides functions of Von Point and Voff Point. When the voltage of tested power
supply goes up untill exceeds the Von Point, the load starts Von test. Once the voltage of tested power
supply is more than the Voff Point,the voltage will drop down till less than the Voff Point, at this time, the
load is in Voff status and the input is in Off status.
When the external input voltage is less than the Von Point, the load will not be enabled even though the
input has been turned on. The load will be enabled till the external input voltage reaches or exceeds the
Von Point.
Von Latch is used to latch the active status of the load. If the Von Latch function is enabled, once the input
voltage reaches Von Point, the input will be turned on, and stay in ON status regardless of the changes
from the external input voltage, even though the input voltage is less than the Von point. Please see figure
3-11;if the Von Latch function is disabled, once the input voltage reaches Von Point, the input will be turned
on automatically, and once the input voltage is less than the Von Point, the input will be automatically
turned off. Please see figure 3-12. The automatically turning on /off of the input can be implemented via
setting the Von Point and Von Latch, which simplifies test operation greatly.
The Von Voltage can be set in main menu, or via the remote command (INPut:VOLTage:ON <NRf+>).
The Voff Voltage can be set in main menu, or via the remote command (INPut:VOLTage:OFF <NRf+>).
The Von Latch can be set in main menu, or via the remote command (INPut:VOLTage:ON:LATCh ON/OFF).

Содержание