AXIOMET AX-EL300W60A [44/72] Short circuit operation
![AXIOMET AX-EL300W60A [44/72] Short circuit operation](/views2/1664975/page44/bg2c.png)
5.6. Short Circuit Operation
The operating procedures for short circuit operation are shown as below:
1) Press “Menu” key to enter into the selectable menu.
2) Use Entry keys or use the knob to select “0 System Set”, and press “Enter” key to confirm and enter into
System Set
3) Select Short (short circuit) item with “↓” key.
4) Operate all the above steps or press “Shift”+“�Short” keys to select Short (short circuit) item.
5) Use Entry keys or knob to set On, and press “Enter” key to confirm.
6) Press “Cancel” key to exit the main menu. The display shows “s” to indicate in the basic test mode.
7) Select one basic test mode; press “Enter” key to confirm and exit the mode selection and parameter
setting menu.
8) Press “On/Off” key to turn on the load.
Example1: The load was in CVH mode previously and it is turned off. Set the load to short circuit in CCH
status. Turn on the load to execute short circuit operation.
Procedures /// Operation Descriptions /// Display
1 /// Press “Menu” key to enter into the selectable menu. /// MENU 0 SYST
2 /// Use Entry keys or use the knob to select “0 System Set”, press “Enter” key to confirm and enter into
System Set. /// CC Set 0 Low
3 /// Use Entry keys or use the knob to select “1 High”, press “Enter” key to confirm. /// CC Set 1 High
4 /// Select Short (short circuit) item with “↓” key. /// SHORT 0Off
5 /// Use Entry keys or knob to set On, and press “Enter” key to confirm. /// SHORT 1On
6 /// Press “Cancel” key to exit the main menu. The display shows “s” to indicate in CVH mode. /// CVH
0.000V
7 /// Select CCH mode by pressing “I-set” key. press “Cancel” key to exit the mode selection and parameter
setting menu. /// CCH 44.000A
8 /// Press “On/Off” key to turn on the load. ///
For the above operating procedures, the corresponding SCPI commands should be:
INPUT:SHORT ON ; Sets the load to short circuit operation
MODE CCH ; Sets mode
INPUT ON ; Turns on the load
Example2: Based on the last example, exit the short circuit operation, and turn off the load.
Procedures /// Operation Descriptions /// Display
1 /// Press “Menu” key to enter into the selectable menu and the load is turned off automatically. /// MENU
0 SYST
2 /// Use Entry keys or use the knob to select “0 System Set”, press “Enter” key to confirm and enter into
System Set. /// CC Set 0 Low
3 /// Use Entry keys or use the knob to select “1 High”, press “Enter” key to confirm. /// CC Set 1 High
4 /// Select Short (short circuit) item with “↓” key. /// SHORT 0On
5 /// Use Entry keys or knob to set Off, and press “Enter” key to confirm. /// SHORT 1Off
Содержание
- Ax el300w programmable dc electronic load operation manual 1
- General introduction 1
- Function features 2
- Production models 2
- Front panel 3
- Message of lcd display 3
- Rear panel 4
- Keypad function 5
- Display messages 9
- Functions and features 10
- Local and remote control 10
- Remote programming 10
- Basic test function 11
- Main function 11
- Transient operation 18
- Sequence list operation 22
- Battery discharge operation 23
- Short circuit operation 24
- Input control 25
- Triggered operation 25
- Measurement function 29
- Saving and recalling 30
- Reading remote programming errors 31
- Status report 31
- Protection function 32
- Auxiliary functions 33
- Connections on the rear panel 34
- Environment installation location 34
- Initial check 34
- Installation 34
- Power on self test 34
- Connections on the front panel 36
- Wiring 36
- Local control 38
- Local operation 38
- Main operation on the front panel 38
- Basic tests 39
- Connecting to the power supply 39
- Turning the input on off 39
- Short circuit operation 44
- Transient operation 45
- Sequence list operation 48
- Battery discharge operation 52
- Saving and recalling 53
- Clear protection settings 54
- Triggered operation 54
- Main menu 55
- Communication interface 59
- Remote control annunciators 59
- Remote programming operation 59
- Sending a remote command 59
- Cc mode example 60
- Remote programming commands 60
- Returning data 60
- Continuous transient operation example 61
- Cr mode example 61
- Cv mode example 61
- Auto test operation 62
- Main menu 62
- Pulsed transient operation example 62
- Function description 63
- Lcd display message 63
- Local operation 63
- Main specifications 67
Похожие устройства
- AXIOMET AX-EL300W Инструкция
- AXIOMET AX-EL300W Расширенная инструкция
- PEAKTECH PKT-P3690 Инструкция по эксплуатации
- PEAKTECH PKT-P3725 Инструкция по эксплуатации
- AXIOMET AX-C709 Инструкция
- AXIOMET AX-C709 Расширенная инструкция
- AXIOMET AX-C708 Инструкция
- AXIOMET AX-C708 Расширенная инструкция
- PEAKTECH PKT-P4390 Инструкция по эксплуатации
- AXIOMET AX-C850 Расширенная инструкция
- AXIOMET AX-C850 Инструкция
- AXIOMET AX-C830 Расширенная инструкция
- AXIOMET AX-C830 Инструкция
- AXIOMET AX-C800 Расширенная инструкция
- AXIOMET AX-C800 Инструкция
- AXIOMET AX-C705 Расширенная инструкция
- AXIOMET AX-C705 Инструкция
- AXIOMET AX-C605 Расширенная инструкция
- AXIOMET AX-C605 Инструкция
- AXIOMET AX-6003P Инструкция