6.7. CV Mode Example
This example presets the trigger voltage to 5V, and selects the external trigger source.
1) ”INPUT OFF” ; Turns off the load’s input
2) ”MODE CVL” ; Selects the CV mode
3) ”VOLT:TRIG 5” ; Presets the trigger voltage value to 5V
4) ”TRIG:SOUR EXT” ; Selects the external input as the trigger source
5) ”INPUT ON” ; Turns on the load’s input
In this example, when the external trigger signal is received, the input voltage will be set to 5V.
6.8. CR Mode Example
This example sets the current protection limit to 3A, sets the time delay to 10s, sets the resistance level to
10Ω, and reads back the computed power.
1) ”INPUT OFF” ; Turns off the load’s input
2) ”MODE CRM” ; Selects the CRM mode
3) ”CURR:PROT:LEV 3 ; Sets the current protection limit to 3A
4) ”CURR:PROT:D EL 10 ; sets the time delay to 10s
5) ”CURR:PROT:STAT ON” ; Activates the current protection
6) ”RES 10” ; Sets the resistance level to 10Ω
7) ”INPUT ON” ; Turns on the load’s input
8) ”MEAS:POW?” ; Measures the input power level
6.9. Continuous Transient Operation Example
This example sets CV transient high/low levels, times for transient rising/falling edge, high/low level times,
and parameters for transient operation.
1) ”INPUT OFF” ; Turns off the load’s input
2) ”MODE CVH” ; Selects the CV mode
3) ”VOLT:LLEV 0.5” ; Sets the transient low level to 0.5V
4) ”VOLT:HLEV 1” ; Sets the transient high level to 1V
5) ”TRAN:LTIM 0.010” ; Sets transient low level time to 10ms
6) ”TRAN:HTIM 0.010” ; Sets transient high level time to 10ms
7) ”TRAN:RTIM 0.010” ; Sets the time for transient rising edge to 10ms
8) ”TRAN:FTIM 0.010” ; Sets the time for transient falling edge to 10ms
9) ”TRAN:MODE CONT ” ; Selects the continuous transient operation
10) ”TRAN ON” ; Activates the transient operation
11) ”INPUT ON” ; Turns on the load’s input