AXIOMET AX-EL300W60A [48/72] Sequence list operation
![AXIOMET AX-EL300W60A [48/72] Sequence list operation](/views2/1664975/page48/bg30.png)
8 /// Use the knob together with “ ”, “ ” keys to set TimeF to 10ms, press “Enter” key to confirm. /// TIMEF
040.00M
9 /// Press “Cancel” key to exit the transient operation menu. ///
10 /// Press “On/Off” key to turn on the load. ///
5.8. Sequence (List) Operation
5.8.0.
After sequence editing, the operating procedures for enabling and disabling sequence operation are shown
as below:
1) Press “List” key to enter into sequence operation menu.
2) Use Entry keys or the knob to set sequence State to On, and press “Enter” key to confirm.
3) Use Entry keys or the knob together with “↑”, “↓” keys to set list number (No.), and press “Enter” key to
confirm.
4) Press “Cancel” key to exit sequence operation menu.
5) Press “Shift”+“4Start” keys to activate sequence operation.
6) Press “Shift”+“5Stop” keys to stop sequence operation.
The operating procedures for sequence operation are shown as below:
1) Press “List” key to enter into sequence operation menu.
2) Use Entry keys or the knob to set sequence State to On, and press “Enter” key to confirm.
3) Use Entry keys or knob to select list number (No.). Press “Enter” key to confirm and recall the sequency
in EEPROM assigned by the sequence number.
4) Use “↓” key to select list memo (Memo).
5) Use knob and “ ”, “ ” keys to edit memo (max. 10 characters).
6) Use “↓” key to select sequence data (Data:<New/Edit>). Use “ ”, “ ” keys keys or knob to select New or
Edit operation.
7) Select “New” operation, and press “Enter” key to enter into data clear screen. Use the knob to select
“Yes” and press “Enter” key to confirm, the data is cleared and meanwhile step edit screen appears. Use
“ ” key or knob to select “No”, press “Enter” key to confirm, in the meantime the load returns to sequence
(list) test menu.
8) Select “Edit” operation, and press “Enter” key to enter into step edit screen.
9) Use “↑”, “↓” keys to select parameters.
10) Use Entry keys or use the knob together with “ ”, “ ” keys to input set value; press “Enter” key to
confirm and enter into the next step.
11) If it is needed to modify one step, use “↑”, “↓” keys to select this step. The setting operations for this
step are the same as the operating procedure 9.
12) If it is needed to add one step to the last step, use “↓” key to select the new step. The setting operations
for this new step are the same as the operating procedure 9.
13) If it is needed to insert one step above an edited step, use “↑”, “↓” keys to select this edited step. The
Содержание
- Ax el300w programmable dc electronic load operation manual 1
- General introduction 1
- Function features 2
- Production models 2
- Front panel 3
- Message of lcd display 3
- Rear panel 4
- Keypad function 5
- Display messages 9
- Functions and features 10
- Local and remote control 10
- Remote programming 10
- Basic test function 11
- Main function 11
- Transient operation 18
- Sequence list operation 22
- Battery discharge operation 23
- Short circuit operation 24
- Input control 25
- Triggered operation 25
- Measurement function 29
- Saving and recalling 30
- Reading remote programming errors 31
- Status report 31
- Protection function 32
- Auxiliary functions 33
- Connections on the rear panel 34
- Environment installation location 34
- Initial check 34
- Installation 34
- Power on self test 34
- Connections on the front panel 36
- Wiring 36
- Local control 38
- Local operation 38
- Main operation on the front panel 38
- Basic tests 39
- Connecting to the power supply 39
- Turning the input on off 39
- Short circuit operation 44
- Transient operation 45
- Sequence list operation 48
- Battery discharge operation 52
- Saving and recalling 53
- Clear protection settings 54
- Triggered operation 54
- Main menu 55
- Communication interface 59
- Remote control annunciators 59
- Remote programming operation 59
- Sending a remote command 59
- Cc mode example 60
- Remote programming commands 60
- Returning data 60
- Continuous transient operation example 61
- Cr mode example 61
- Cv mode example 61
- Auto test operation 62
- Main menu 62
- Pulsed transient operation example 62
- Function description 63
- Lcd display message 63
- Local operation 63
- Main specifications 67
Похожие устройства
- AXIOMET AX-EL300W Инструкция
- AXIOMET AX-EL300W Расширенная инструкция
- PEAKTECH PKT-P3690 Инструкция по эксплуатации
- PEAKTECH PKT-P3725 Инструкция по эксплуатации
- AXIOMET AX-C709 Инструкция
- AXIOMET AX-C709 Расширенная инструкция
- AXIOMET AX-C708 Инструкция
- AXIOMET AX-C708 Расширенная инструкция
- PEAKTECH PKT-P4390 Инструкция по эксплуатации
- AXIOMET AX-C850 Расширенная инструкция
- AXIOMET AX-C850 Инструкция
- AXIOMET AX-C830 Расширенная инструкция
- AXIOMET AX-C830 Инструкция
- AXIOMET AX-C800 Расширенная инструкция
- AXIOMET AX-C800 Инструкция
- AXIOMET AX-C705 Расширенная инструкция
- AXIOMET AX-C705 Инструкция
- AXIOMET AX-C605 Расширенная инструкция
- AXIOMET AX-C605 Инструкция
- AXIOMET AX-6003P Инструкция