3.14. Protection Function
3.14.0.
The electronic load is equipped with the following protection functions:
- Overvoltage (OV)
- Overcurrent (OC)
- Overpower (OP)
- Overtemperature (OT)
- Reverse Voltage (RV)
Once any of the above protection functions is active, the corresponding status bit in the status will be set;
the input will be turned off with beeps; the annunciator of “Cancel” will be turned on, the display will
show PT to indicate protection status the detected conditions will be displayed; the load will enter into
the latched protection status, and will not respond to other commands except some specific operations.
For example: if an overtemperature conditions has been detected, the input will be turned off with beeps,
and OT will be shown in the lower right corner of the display. The load will have no response to other
operations.
3.14.1. Clearing Latched Protection
When the load enters into the latched protection status, it will have no response to other commands. The
load will return to the normal operation only when the latched protection has been reset via long pressing
the “Cancel” key or the remote command (INPut:PROTection:CLEar). Of course, the condition that cause
the latched protection must be removed, or it will be latched again as soon as it is reset.
In addition, when the software overcurrent protection is enabled, if the overcurrent time does not exceed
the specified protection time, the indicator of “Cancel” will be turned on, but the input will not be turned
off. At this time, you can reset the overcurrent time via long-pressing “Cancel” key or the remote command
(INPut:PROTection:CLEar).
3.14.2. Over Voltage
When the input voltage exceeds the predetermined voltage, the overvoltage protection will be enabled, and
the input is turned off with OVP displayed, meanwhile, the OV and VF status register bits are set, and will
remain set until they are reset and overvoltage condition is removed.
3.14.3. Over Current
The electronic load allows the user to define a current protection limit. When the defined current limit is
exceeded, the overcurrent timer starts timing, and the indicator of “Cancel” will be turned on, but the input
will not be turned off immediately. When the specified delay time is reached, the overcurrent protection
will be enabled and the input is turned off with OCP displayed, meanwhile, the OC and PS status register
bits are set, and will remain set until they are reset and overcurrent condition is removed. The current
protection limit function can only be set via the entry key from the front panel and the remote command.
It is turned on/off with the command (CURRent:PROTection:STATe ON/OFF). The current limit level is
Содержание
- Ax el300w programmable dc electronic load operation manual 1
- General introduction 1
- Function features 2
- Production models 2
- Front panel 3
- Message of lcd display 3
- Rear panel 4
- Keypad function 5
- Display messages 9
- Functions and features 10
- Local and remote control 10
- Remote programming 10
- Basic test function 11
- Main function 11
- Transient operation 18
- Sequence list operation 22
- Battery discharge operation 23
- Short circuit operation 24
- Input control 25
- Triggered operation 25
- Measurement function 29
- Saving and recalling 30
- Reading remote programming errors 31
- Status report 31
- Protection function 32
- Auxiliary functions 33
- Connections on the rear panel 34
- Environment installation location 34
- Initial check 34
- Installation 34
- Power on self test 34
- Connections on the front panel 36
- Wiring 36
- Local control 38
- Local operation 38
- Main operation on the front panel 38
- Basic tests 39
- Connecting to the power supply 39
- Turning the input on off 39
- Short circuit operation 44
- Transient operation 45
- Sequence list operation 48
- Battery discharge operation 52
- Saving and recalling 53
- Clear protection settings 54
- Triggered operation 54
- Main menu 55
- Communication interface 59
- Remote control annunciators 59
- Remote programming operation 59
- Sending a remote command 59
- Cc mode example 60
- Remote programming commands 60
- Returning data 60
- Continuous transient operation example 61
- Cr mode example 61
- Cv mode example 61
- Auto test operation 62
- Main menu 62
- Pulsed transient operation example 62
- Function description 63
- Lcd display message 63
- Local operation 63
- Main specifications 67
Похожие устройства
- AXIOMET AX-EL300W Инструкция
- AXIOMET AX-EL300W Расширенная инструкция
- PEAKTECH PKT-P3690 Инструкция по эксплуатации
- PEAKTECH PKT-P3725 Инструкция по эксплуатации
- AXIOMET AX-C709 Инструкция
- AXIOMET AX-C709 Расширенная инструкция
- AXIOMET AX-C708 Инструкция
- AXIOMET AX-C708 Расширенная инструкция
- PEAKTECH PKT-P4390 Инструкция по эксплуатации
- AXIOMET AX-C850 Расширенная инструкция
- AXIOMET AX-C850 Инструкция
- AXIOMET AX-C830 Расширенная инструкция
- AXIOMET AX-C830 Инструкция
- AXIOMET AX-C800 Расширенная инструкция
- AXIOMET AX-C800 Инструкция
- AXIOMET AX-C705 Расширенная инструкция
- AXIOMET AX-C705 Инструкция
- AXIOMET AX-C605 Расширенная инструкция
- AXIOMET AX-C605 Инструкция
- AXIOMET AX-6003P Инструкция